Dynamax AVRD 3.2 Manuale di installazione e funzionamento - Pagina 10

Sfoglia online o scarica il pdf Manuale di installazione e funzionamento per Controllore Dynamax AVRD 3.2. Dynamax AVRD 3.2 12. Voltage regulator

SYSTEMS WITH VOLTAGE REGULATION
Model
Flow2
Flow32-A
Flow32-B
Flow32-C
FLGS-TDP
FL32-GS8
FL32-GS16
FLDL-TDP
DL2e
DL3000
SV1 (Delta-T Devices Kit)
The specific sensor excitation voltage requirements are found in the installation manual for
that sensor. To determine the voltage for specific conditions and the type of sensor refer
to the sensor installation manual. The following table gives a quick picture of the typical
voltage requirements.
SENSOR REQUIREMENTS
Model
SGA2-3
SGA5
SGA10-SGB25
SGB35-SGA70
SGA100
TDP-10-50
TDP-80
TDP-100

4.0 Safety and Maintenance

PRECAUTIONS
1. The AVRD series regulators are not waterproof. The AVRD's should be installed in
protected enclosures, NEMA 2,3 or 4 rated.
2. The regulator is internally protected from over-current. Nevertheless, do not short output
(+) leads to ground or minus leads. This can cause damage to wires, the regulator and
eventually burn up the device.
3. In addition to over-current latching AVRD is protected by an external in-line fuse 15A; 5 x
20mm (considering 5A max current on each).
Regulator Included Standard
Internal 1A
AVRD
AVRD
AVRD
(2) AVRD
AVRD
(2) AVRD
-
-
-
-
Type
Dynagage Microsensors
Dynagage Microsensor
Dynagage Stem Gauges
Dynagage Trunk Gauges
Dynagage Trunk Gauges
Granier Sap Velocity Sensor
Dual Sap Velocity Sensor
Triple Sap Velocity Sensor
Maximum Upgraded System - Add:
AVRD
AVRD
AVRD
AVRD
-
AVRD
-
AVRD
AVRD
AVRD
AVRD
Range
2-3 V
3.5-4.5 V
3.5-5 V
5-7 V
6-10 V
2-5 V
7.5 V
8 V
9