ADEMCO 4208U Manuale di installazione e configurazione - Pagina 2
Sfoglia online o scarica il pdf Manuale di installazione e configurazione per Unità di controllo ADEMCO 4208U. ADEMCO 4208U 4. Universal eight zone remote point module
DIP Switches
REED (TAMPER) SWITCH
TB1
2
3
4
5
6
1
7
8
10k 10k
10k 10k
10k 10k
LOOPS: A
B
C
D
E
When using this mode, program each zone's "Input Type" as "DIP Switch Polling Loop Device" (DP), where applicable.
DIP Switch Position
("-" Means "off")
2
3
4
ON
ON
ON
ON
ON
ON
ON
ON
-
ON
ON
-
ON
-
ON
ON
-
ON
ON
-
-
ON
-
-
-
ON
ON
-
ON
ON
-
ON
-
-
ON
-
-
-
ON
-
-
ON
-
-
-
-
-
-
4208U
TB2
NOT
5
USED
( ) GROUND
4
3
(+) 12V
TO
2
( )
POLLING
LOOP
1
(+)
(USE
TWISTED
PAIR)
9
10 11 12
(EACH LOOP'S MAX
RESISTANCE:
300 ohms + 10k EOLR)
10k 10k
F
G
H
Figure 2: Summary of Connections
For "Zone Assignment" mode, DIP Switch position 6 must be off.
THIS SWITCH SETTING PRESETS THE LOOPS TO THESE ZONE NUMBERS
DIP Switch Position
("-" Means "off")
2
3
4
5
6
A
On
On
On
On
-
1
On
On
On
-
-
9
On
On
-
On
-
17
On
On
-
-
-
25
On
-
On
On
-
33
On
-
On
-
-
41
On
-
-
On
-
49
On
-
-
-
-
57
-
On
On
On
-
65
-
On
On
-
-
73
-
On
-
On
-
81
-
On
-
-
-
89
-
-
On
On
-
97
-
-
On
-
-
105
-
-
-
On
-
113
-
-
-
-
-
121
*Do not select 1 – 8 for VISTA controls.
**If 9 – 16 is selected for controls that have 9 hardwire zones. Loop A (Zone 9) will be inactive.
***Accommodates option "ONE 4208 IN USE" if referred to in control programming.
NOTE: Consult the Control Panel Instructions to determine the valid zone numbers for that control panel.
Table 1. 4208U Zone Assignments
THIS SWITCH SETTING PRESETS THE LOOP TO THESE SERIAL NUMBERS
5
6
LOOP A
ON
ON
000-4116
-
ON
006-9908
ON
ON
013-9812
-
ON
020-9716
ON
ON
027-9620
-
ON
034-9524
ON
ON
041-9428
-
ON
048-9332
ON
ON
055-9236
-
ON
062-9140
ON
ON
069-9044
-
ON
076-8948
ON
ON
083-8852
-
ON
090-8756
ON
ON
097-8660
-
ON
104-8564
Table 2. 4208U Serial Number Assignments
NOTE
FOR CE INSTALLATIONS A
N6361 EMI SUPPRESSION
BEAD IS REQUIRED.
OFF
SIDEVIEW
4208U-SOC-V0
Loop Designations
B
C
D
E
F
2
3
4
5
6
10
11
12
13
14
18
19
20
21
22
26
27
28
29
30
34
35
36
37
38
42
43
44
45
46
50
51
52
53
54
58
59
60
61
62
66
67
68
69
70
74
75
76
77
78
82
83
84
85
86
90
91
92
93
94
98
99
100
101
102
106
107
108
109
110
114
115
116
117
118
122
123
124
125
126
Loop Designation
LOOP B
LOOP C
LOOP D
000-4117
000-4118
000-4119
006-9909
006-9910
006-9911
013-9813
013-9814
013-9815
020-9717
020-9718
020-9719
027-9621
027-9622
027-9623
034-9525
034-9526
034-9527
041-9429
041-9430
041-9431
048-9333
048-9334
048-9335
055-9237
055-9238
055-9239
062-9141
062-9142
062-9143
069-9045
069-9046
069-9047
076-8949
076-8950
076-8951
083-8853
083-8854
083-8855
090-8757
090-8758
090-8759
097-8661
097-8662
097-8663
104-8565
104-8566
104-8567
2
ON
POSITION 1:
SELECT RESPONSE TIME
FOR LOOPS A and B
(SHOWN ON = SLOW).
POSITIONS 2-5: SELECT THE 8 SENSOR
DEVICE GROUP ADDRESS
(SHOWN ON, ON, ON,
OFF = 2nd GROUP SELECTION).
POSITION 6:
DEVICE TYPE (SHOWN
ON = "SERIAL NUMBER MODE").
POSITION 7:
NOT USED (SET TO "OFF").
ON
POSITION 8:
SELECT TAMPER PROTEC-
TION SETTING (SHOWN
"OFF" = TAMPER ENABLED).
G
H
*
7
8
**
15
16
23
24
31
32
39
40
47
48
55
56
63
64
71
72
79
80
87
88
95
96
103
104
111
112
119
120
***
127
N/A
LOOP E
LOOP F
000-4124
000-4125
006-9916
006-9917
013-9820
013-9821
020-9724
020-9725
027-9628
027-9629
034-9532
034-9533
041-9436
041-9437
048-9340
048-9341
055-9244
055-9245
062-9148
062-9149
069-9052
069-9053
076-8956
076-8957
083-8860
083-8861
090-8764
090-8765
097-8668
097-8669
104-8572
104-8573
4208U-001-V0
LOOP G
LOOP H
000-4126
000-4127
006-9918
006-9919
013-9822
013-9823
020-9726
020-9727
027-9630
027-9631
034-9534
034-9535
041-9438
041-9439
048-9342
048-9343
055-9246
055-9247
062-9150
062-9151
069-9054
069-9055
076-8958
076-8959
083-8862
083-8863
090-8766
090-8767
097-8670
097-8671
104-8574
104-8575