8. TECHNICAL APPENDIX
1).INSTALLATION INSTRUCTIONS
The installation of the valve is carried out by screwingor sliping in, of the available connections according to the
installation scheme.
It is recommended to use adapter unions. Maintenance works and replacement are also
easier by using adapter unions.
2).FUNCTION AND INSTALLATION SCHEME
I. Filtration of Medium (i.e. Water)
Pool => Pump => Valve (to filter) =>
filter => Valve (from filter) => Pool
III. No Circulation
Do not operate pump.
Pool => Pump => Valve
V. Recirculation of Fluid Without
Filter (by pass filter)
Pool => Pump => Valve => Pool
9.Warning
1. THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE
CIRCULATING SYSTEM (e.g. CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN
ENTER THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED AIR CAN CAUSE THE LID
OR VALVE TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR
PROPERTY DAMAGE.DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE FILTER
OPERATING.
NOTE
2. TURN PUMP OFF BEFORE CHANGING VALVE POSITION.
3. TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM,
CLEAN PUMP STRAINER AND SKIMMER BASKET REGULARLY.
II. Drainage of Pool with Pump
Pool => Pump => Valve => Canal
IV. Cleaning of Filter Medium (i.e. Sand)
in upstream (reserved flow in filter)
Pool => Pump => Valve (from filter) =>
filter => Valve (to filter) => Waste
VI. Cleaning of Filter Medium (i.e. Sand)
after Backwash
Pool => Pump => Valve (to filter) => filter
=> Valve (from filter) => Waste
Figure 4