Autonics AS80-50D Manuale del prodotto - Pagina 2
Sfoglia online o scarica il pdf Manuale del prodotto per Accessories Autonics AS80-50D. Autonics AS80-50D 3. Rectangular inductive long-distance proximity sensors
Ordering Information
This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.
AS
80
-
50
D
❶ Control output
N3: NPN Normally Open + Normally Closed
P3: PNP Normally Open + Normally Closed
Product Components
• Bracket
× 1
• M5 Bolt × 4
Connections
■ Cable type
Brown
LOAD
Black
LOAD
NPN
White
Blue
■ Inner circuit (NPN output)
LOAD
N.O.
LOAD
N.C.
Operation Timing Chart
Normally open
Presence
Sensing target
Nothing
Operation
Load
Return
H
NPN
output
L
Output
voltage
H
PNP
output
L
ON
Operation
indicator (yellow)
OFF
❶
Brown
Black
PNP
LOAD
White
LOAD
Blue
■ Inner circuit (PNP output)
N.C.
LOAD
Normally closed
Presence
Nothing
Operation
Return
H
L
H
L
ON
OFF
Specifications
Installation
Model
Sensing side length
Sensing distance
Setting distance
Hysteresis
Standard sensing
target: iron
Response frequency
Affection by
temperature
Indicator
Approval
Unit weight
01) The response frequency is the average value. The standard sensing target is used and the width is set as
2 times of the standard sensing target, 1/2 of the sensing distance for the distance.
Power supply
Current consumption
Control output
Residual voltage
Protection circuit
Insulation type
Dielectric strength
Vibration
Shock
Ambient temperature
Ambient humidity
Protection structure
N.O.
Connection
Wire spec.
LOAD
Connector spec.
Material
Upper side type
AS80-50D□
80 mm
50 mm
0 to 35 mm
≤ 15 % of sensing distance
150 × 150 × 1 mm
30 Hz
01)
± 10 % for sensing distance at ambient temperature 20 ℃
Power indicator (green), operation indicator (yellow)
ᜢ ᜫ
≈ 470 g
12 - 48 VDCᜡ (ripple P-P: ≤ 10 %), operating voltage: 10 - 65 VDCᜡ
≤ 20 mA
≤ 200 mA
≤ 2 V
Surge protection circuit, output short over current protection
circuit, reverse polarity protection
≥ 50 MΩ (500 VDCᜡ megger)
1,500 VACᜠ 50/60 Hz for 1 minute
1 mm double amplitude at frequency 10 to 55 Hz (for 1 min) in
each X, Y, Z direction for 2 hours
500 m/s² (≈ 50 G) X, Y, Z directions for 3 times
-25 to 70 ℃, storage: -30 to 80 ℃ (no freezing or condensation)
35 to 95 %RH, storage: 35 to 95 %RH (no freezing or condensation)
IP67 (IEC standard)
Cable type model
Ø 5 mm, 4-wire, 2 m
AWG 22 (0.08 mm, 60-core), insulator diameter: Ø 1.25 mm
Case: PC+ABS, standard type cable (black): polyvinyl chloride (PVC)