2GIS 2GIG-SDS1-345 Manuale d'uso
Sfoglia online o scarica il pdf Manuale d'uso per Accessories 2GIS 2GIG-SDS1-345. 2GIS 2GIG-SDS1-345 4. Smoke detector sensor
INSTR,INSTL,2GIG-SDS1-345 - P/N: 10010592 X8- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.500" X 11.000" - TOL. +/- 0.020"- SCALE: 1-1 - PAGE 1 OF 2- FOLDING: FOLD 1X TO FINAL SIZE: 8.500" X 5.500"- FINISH WITH LOGO SHOWING
2GIG-SDS1-345
SMOKE DETECTOR SENSOR
GENERAL INFORMATION
The 2GIG Smoke Detector Sensor, part number 2GIG-SDS1-345, is a 110V AC
powered sensor. It monitors the interconnect line on interconnected hardwired
smoke detector systems and sends out a transmission when smoke is detected
at any of the smoke alarm units connected on the same circuit. The device has
LEDs to visually indicate the status of the sensor. A single CR2032 ba ery provides
backup power in the event that AC power is lost on the smoke detector system
circuit. The smoke detector sensor communicates with a compa ble 2GIG control
panel and can send alarm, low ba ery, AC power loss, and supervisory messages
to the system's receiver.
Contents of Carton:
• 1-Smoke Detector Sensor
• 2-2" long 10-32 Screws
• 1-CR 2032 3 Volt Coin Ba ery
CR2032
COIN BATTERY
+
CR2032
3V
10-32 X 2"
SCREWS
Figure 1. 2GIG-SDS1 Kit
IMPORTANT: This device must be tested and maintained regularly. This device
is intended for use with compa ble smoke detectors, but will not detect the
presence of smoke, heat, or fi re directly.
✓ Note: Each of the smoke alarms part of interconnected smoke alarms must be:
• Present in every required loca on per NFPA 72,11.5.1
• Confi rmed as less than ten years from date of installa on (or manufacture).
Please check label on the device or original smoke detector device manual.
• Hardwired to a single, common 120V AC circuit designated for interconnected
smoke alarms.
• Pass the manufacturer's stated tes ng regimen to confi rm proper interconnect
opera on.
• Have fresh back-up ba eries.
• On the list of compa ble models (any model not listed may work but has not
been compa bility tested.
• This device shall not be installed in loca ons where the normal ambient
temperature is below 40F(4.4C) or exceeds 100F (37.8C), unless the alarm has
been determined capable of being used at installa on points with higher or
lower ambient temperatures.
• Please see sec on at the end regarding informa on on the proper installa on
of smoke detectors that are intended to work with the Smoke Detector Sensor.
• This device is not intended to work with smoke alarms paired with smoke alarm
guards, unless the combina on has been evaluated and found suitable for this
purpose.
Compatible Smoke Alarm Models
• BRK Brands Model 7010B: AC Powered Photoelectric Smoke Alarm with Ba ery Backup
• Firex Kidde Model i4618: Hardwire Ioniza on Smoke Detector with Ba ery Backup
• First Alert BRK Model 9120B: Hardwired Smoke Alarm with Ba ery Backup
• Kidde Model i12040: 120V AC Wire-in Smoke Alarm with Ba ery Backup
• USI Electric Model 5304: Hardwired Ioniza on Smoke and Fire Alarm with
Ba ery Backup
PRINTER'S INSTRUCTIONS:
CAUTION: Before a emp ng installa on, locate the primary electrical circuit
that powers the interconnected hardwired smoke detector system and shut off
or disconnect power to this circuit. An electrical shock hazard is present if this
electrical circuit is not temporarily disabled during installa on.
WARNING: Remember to turn on or reconnect power to the primary electrical
circuit that powers the interconnected hardwired smoke detector system. The fi re
warning system may be disabled if electrical power is not restored to the system
Install Sensor
Select a smoke detector that will be used to provide power and communicate to
the smoke detector sensor. Any smoke detector that is within range of a wireless
2GIG receiver can be selected if the smoke detector is part of an interconnected
hardwired system.
Remove the exis ng smoke detector from the exis ng moun ng bracket. This is
usually done by twis ng the detector counter clockwise or clockwise from where
it is mounted.
SMOKE DETECTOR
SENSOR
WIRETAPS
Figure 2. Remove Exis ng Smoke Detector from Smoke Detector Moun ng Bracket
Figure 3. Unplug Pigtail of Exis ng Smoke Detector
Unplug the exis ng smoke detector from the smoke detector pigtail. Loosen the
two screws used to hold the exis ng moun ng bracket and remove it from the
wall or ceiling.
Figure 4. Remove Exis ng Smoke Detector Moun ng Bracket from Wall or Ceiling
EXISTING
SMOKE
DETECTOR
MOUNTING
BASE
ROTATE
COUNTER
CLOCKWISE
TO REMOVE
SMOKE
EXISTING
SMOKE
DETECTOR
EXISTING SMOKE
DETECTOR
UNPLUG
SMOKE DETECTOR
FROM EXISTING
POWER PIGTAIL
EXISTING SMOKE DETECTOR
MOUNTING BRACKET
REMOVE EXISTING SMOKE
REMOVE
DETECTOR MOUNTING
EXISTING
BRACKET FROM WALL OR
SCREWS
CEILING
Copyright © 2016 Nortek Security & Control 1
ACCESS HOLE
IN WALL OR
CEILING
EXISTING
SMOKE
DETECTOR
POWER
PIGTAIL