CellarCool ADDENDUM CM Series Manuale di avvio rapido - Pagina 9
Sfoglia online o scarica il pdf Manuale di avvio rapido per Raffreddatore per vino CellarCool ADDENDUM CM Series. CellarCool ADDENDUM CM Series 12.
INSULATION BLANKET INSTALLATION, CONTINUED
1. evaporator unit as a template. Remove excess insulation. Proceed to piece (B) installation.
2. Spray the top of the evaporator unit with spray adhesive. (See spray adhesive directions for proper tack time
before proceeding to step 8.)
3. Set piece (B) in place by pressing firmly on all surfaces of the insulation that come in contact with the top of the
A
evaporator unit (see illustration).
If needed, trim excess insulation around all edges.
4. Using a utility knife, cut holes in the insulation for line set, wiring, and drain line if needed.
5. Once insulation is installed, apply foil tape to all seams, covering them completely.
6. Inspect insulation for damage/defects. If damaged, repair with foil tape.
7. Apply cork tape or equivalent to areas where the line set, wiring, and drain line enter the unit.
A
B
CM SERIES - Addendum
B
A
www.cellarcool.com | Page 7