Dynamix RC 907 EV 35 Manuale d'uso - Pagina 8

Sfoglia online o scarica il pdf Manuale d'uso per Convertitore multimediale Dynamix RC 907 EV 35. Dynamix RC 907 EV 35 16. Ethernet to v.35 interface converter

2.3 Duplex Mode Configuration

RC907/908-EV35 series Ethernet to V.35 interface converters are devices used to
conduct media conversions and extend transmission distances. When connecting
RC907/908-EV35 interface converters with other network equipment, they need to
cooperate with each other to work properly. Different duplex mode configurations
on network equipment interfaces will affect the transmission efficiency of the
network. The recommended configurations are listed in the following table when
interconnecting different network equipment.
The working mode of other network
equipment
10Mbps full duplex
10Mbps half duplex
Auto-negotiation
100Mbps full duplex
100Mbps half duplex
2.4 Connection with other network equipment (at
Ethernet port)
RC907/908-EV35 series interface converter supports MDI/MDIX auto-sensing.
RC907/908-EV35 User Guide
RC907/908-EV35 working mode
The
interface
configured to full duplex mode when
auto-negotiation
The
interface
configured to half duplex mode when
auto-negotiation fails. (Factory default)
No need for configuration. (Factory
default)
The interface converter cannot connect
with 100Mbps interfaces of other
equipment.
The interface converter cannot connect
with 100Mbps interfaces of other
equipment.
converter
shall
fails.
converter
shall
be
be