Autonics TC4Y Manuale - Pagina 8

Sfoglia online o scarica il pdf Manuale per Regolatore di temperatura Autonics TC4Y. Autonics TC4Y 14. Touch switch type temperature controller
Anche per Autonics TC4Y: Manuale (14 pagine), Manuale (2 pagine), Manuale di istruzioni (2 pagine), Manuale di avvio rapido (9 pagine), Manuale di avvio rapido (10 pagine)

Autonics TC4Y Manuale
SV low-limit value
S
L-SV
SV high-limit value
S
H-SV
Control output operation
S
O-FT
Control type
S
C-MD
Control output type
S
OUT
SSR dirve output method
S
SSrM
Control cycle
S
T
AL1 alarm operation
S
AL-1
AL2 alarm operation
S
AL-2
Alarm output hysteresis
S
AHYS
LBA monitoring time
S
LBaT
LBA detection band
S
LBaB
Digital input key
S
DI-K
Control output MV in case
of input break error
S
ErMV
Parameter lock
S
LOC
Setting range: Within the rated temperature range by
-050
input sensor [ L-SV ≤ ( H-SV -1digit)]
※ W hen changing SV low-limit value, if SV< L-SV , SV is
initialized as L-SV .
Setting range: Within the rated temperature range by
1200
input sensor [ H-SV ≥ ( L-SV +1digit)]
※ W hen changing SV high-limit value, if SV> H-SV , SV is
initialized as H-SV .
HEAT
COOL
※ When changing control output operation, ErMU is initialized.
※ When changing control type, ErMU is initialized (control output
PID
ONOF
MV is below 100%) and DI-K turns OFF automatically.
※ Operates only selected output between Relay or SSR.
RLY
SSR
STND
CYCL
PHAS
Setting range:0.5 to 120.0 sec.
02)0
※If control output [ OUT ] is set as RLY , factory default is 20.0 sec, or set as SSR drive output
[ SSR ], factory default is 2.0 sec.
※ThisTwillnotbedisplayedwhenSSRdriveoutputmethod [ SSrM ] is set as CYCL , PHAS .
AMiA
LBaA
※ Alarm operation
※ Same with the above [ AL-1 ].
AM@A
※WhenchangingalarmoperationAL1,AL2alarmtemperatureof
AL1,AL2isinitialized.
Setting range: 1 to 100℃/℉ ( DPtL / CYsL : 0.1 to 50.0℃)
00I
※ If AL1, AL2 alarm operation [ AL-1 , AL-2 ] is set to AM)_ , SBa , LBA , AHYS parameter is
not displayed.
Setting range: 0 to 9999sec. (Automatically setting with Auto-tuning)
0
※ LBaT parameter is displayed when AL1, AL2 alarm operation [ AL-1 , AL-2 ] is set as LBA .
Setting range: 0 to 999℃/℉( DPtL / CUs : 0.0 to 999.9℃/℉)
002
(automatically setting with auto-tuning)
※ When alarm operation mode [ AL-1 , AL-2 ] is set as loop break alarm (LBA) [ LBA ], and
LBaT parameter does not set as 0, LBaB parameter is displayed.
OFF
STOP
※ AlREisnotdisplayedfornotalarmoutputmodel.
※ ATisnotdisplayedwhencontroltypeparameter[C-MD]issetONOF.
Setting range: 0.0 to 100.0%
※ 0.0/100.0% is displayed when control type parameter [ C-MD ] is set ONOF .
00)0
※WhenchangingPIDcontroltoON/OFFcontrol,ifMVisbelow100.0%,itisinitializedas0.0%.
OFF
LOC1
LOC2
Economical PID Control
※ It is displayed when selecting control output [ OUT ] as SSR .
For AC/DC power type (TC4 - 2R), this parameter [ SSrM ]
is not displayed.
AM!A
AMiB
※ Alarm option
Press
the set function. For more information, refer to
AlRE
AT
Functions ' Digital input key'.
※ For indicator model (TC4 -N N),
LOC3
only OFF , LOC1 are available.
※ I n case of changing input
sensor type [ IN-T ], it changes
automatically as max./min. value
of the changed input sensor.
※ Press
key to convert alarm
operation mode into alarm option.
※ Refer to page H-62.
+
keys for 3 sec. and it executes
(A)
Photoelectric
Sensors
(B)
Fiber
Optic
Sensors
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
(E)
Pressure
Sensors
(F)
Rotary
Encoders
(G)
Connectors/
Sockets
(H)
Temperature
Controllers
(I)
SSRs / Power
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(M)
Tacho /
Speed / Pulse
Meters
(N)
Display
Units
(O)
Sensor
Controllers
(P)
Switching
Mode Power
Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
H-61