LIVE FILTERS CAN SET TO ONE OF THREE FILTER LIFT SELECTIONS:
This sets the amount of time a live filter remains in effect before it becomes disengaged.
Filters settings are:
Live Filter Lift Time Menu
• Live Filter Lift Off – The filter remains in effect until all other available filters are in use and
it is needed again in a new position. The filter acts in a "round robin" capacity rotating in
line to address problems as they occur.
• Live Filter Lift 10 Minutes – The filter remains in place for 10 minutes, then checks to see
if it is still needed before it releases and is available for use again.
• Live Filter Lift 1 Hour – The filter remains in place for 1 hour, then checks to see if it is
still needed before it releases and is available for use again.
TO SELECT LIVE FILTER LIFT SETTINGS:
1. On power up, press and hold channel 1 AFS button until the Channel 1 meters show every
other LED lit.
2. Once the AFS button is released, the various modes can be selected.
3. Pressing the Channel 1 AFS button cycles through the menus. This is indicated by changes
in the LED's on the Channel 1 output meters.
4. Press the Channel 1 AFS button until it lights up the Second LED on the Channel 1 output
Meter indicating that you are in the Live Filter Lift Selection mode.
5. Pressing the Channel 2 AFS allows you to toggle between the three settings indicated by
LED's on Channel 2 output meter.
6. Pressing and holding the Channel 1 AFS button will allow you to exit the power up menus,
or proceed to instruction #4 below in "Front Panel Control Lock Out Feature."
Live Filter Lift Off
Live Filter Lift 10 Minutes
Live Filter Lift one Hour
CHANNEL 2
(1st LED)
(2nd LED)
(3rd LED)
The 3 Live