Autonics MT4Y Series Manuale del prodotto - Pagina 3
Sfoglia online o scarica il pdf Manuale del prodotto per Strumenti di misura Autonics MT4Y Series. Autonics MT4Y Series 6. 4-digit multi panel meters
Anche per Autonics MT4Y Series: Manuale (12 pagine)
Specifications
Model
MT4Y-DV-4□
Input type
DC voltage
Max. allowable input 110 % F.S. for each measured input range
Display method
7-segment (red) LED (character height: 14.2 mm)
Display accuracy
Dependent on the ambient temperature
± 0.1 % F.S. rdg
23 ± 5 ℃
± 2 digit
-10 to 50 ℃
± 0.5 % F.S. rdg ± 3 digit
Max. display range
-1999 to 9999 (4 digit)
A / D conversion
ΣΔ (Sigma Delta) ADC
method
Sampling cycle
50 ms
Unit weight
≈ 134 g (≈ 213.5 g)
(packaged)
Approval
ᜢ ᜧ ᜫ
01) Available frequency display, Display accuracy (23 ± 5 ℃): ± 0.1 % F.S. rdg ± 2 digit
02) 5 A terminal: ± 0.3 % F.S. rdg ± 3 digit
None (indicator) / Relay / NPN open collector / PNP open collector
Preset output
output model
Contact capacity: 250 VACᜠ 3 A, 30 VDCᜡ 3 A
Relay
Contact composition: N.O (1a)
NPN / PNP
Output capacity: ≤ 12 - 24 VDCᜡ ± 2 VDCᜡ, 50 mA resistive load
open collector
None (indicator) / BCD Dynamic / Transmission (DC 4 - 20 mA) /
Sub output
Low speed serial / RS485 Communication output model
BCD Dynamic /
NPN open collector output
Low speed serial
Output capacity: ≤ 12 - 24 VDCᜡ, 50 mA resistive load
Transmission
Resolution: 1/12,000 (load resistance: ≤ 600 Ω)
(DC 4 - 20 mA)
Response time: ≤ 450 ms
RS485 communication
Protocol: Modbus RTU
Power supply
100 - 240 VACᜠ ± 10 % 50 / 60 Hz
Power consumption
5 VA
Insulation resistance
Between external terminal and case: ≥ 100 MΩ (500 VDCᜡ megger)
Dielectric strength
Between external terminal and case: 2,000 VACᜠ 50 / 60 Hz for 1 min
Noise immunity
± 2 kV square wave noise (pulse width: 1 ㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in
Vibration
each X, Y, Z direction for 2 hours
Vibration
0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in
(malfunction)
each X, Y, Z direction for 10 min
300 m/s
(≈ 30 G) in each X, Y, Z direction for 3 times
Shock
2
Shock (malfunction)
100 m/s
(≈ 10 G) in each X, Y, Z direction for 3 times
2
Mechanical: ≥ 20,000,000 operations
Relay life cycle
Electrical: ≥ 100,000 operations (250 VACᜠ 3A resistive load)
Ambient temp.
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humi.
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Symbol: , double or reinforced insulation (dielectric strength between
Insulation type
the measurement input part and the power part: 1 kV)
Communication Interface
■ RS485
Comm. protocol
Modbus RTU
Application standard
Compliance with EIA RS485
Max. connection
31 units (address: 01 to 99)
Comm. synchronous method Asynchronous
Comm. method
2-wire half duplex
Comm. distance
≤ 800 m
Comm. speed
1,200 / 1,400 / 4,800 / 9,600 / 19,200 / 38,400 bps
Start bit
1-bit (fixed)
Data bit
8-bit (fixed)
Parity bit
None, Even, Odd
Stop bit
1-bit, 2-bit
EEPROM life cycle
≈ 1,000,000 operations (Erase / Write)
MT4Y-DA-4□
MT4Y-AV-4□
MT4Y-AA-4□
DC current
AC voltage
AC current
01)
± 0.1 % F.S. rdg
± 0.3 % F.S. rdg
± 0.3 % F.S. rdg
± 2 digit
± 3 digit
± 3 digit
02)
16.6 ms
Mode Setting
[MODE] 3 sec
01)
[MODE] 5 sec
RUN
[MODE]
[◀] + [▲] 3 sec
[◀] + [▲] + [▼] 5 sec
Parameter Setting
• Some parameters are activated / deactivated depending on the model or setting of
other parameters. Refer to the description of each parameter.
• If any key is not entered for 60 sec in each parameter, it returns to RUN mode.
• After returning to RUN mode, press the [MODE] key within 2 sec, it returns to
previous parameter.
• [MODE] key: Saves current setting value and moves to the next parameter.
[◀] key: Checks fixed value / Changes setting digits.
[▲], [▼] key: Changes setting values.
■ Parameter 1 group
Parameter
Mark
1-1
Input range
IN-R
Display
1-2
method
DISP
Measurement
1-3
method
IN-T
Max. display
1-4
value
STND
(fixed)
High-limit
display value
1-5
gradient
INbH
correction
Low-limit
display value
1-6
deviation
INbL
correction
Decimal
1-7
point
DOT
position
1-8
High-limit scale H-SC -
1-9
Low-limit scale L-SC -
High-limit
display value
1-10
gradient
INbH
correction
Low-limit
display value
1-11
deviation
INbL
correction
02)
Decimal
1-12
point
DOT
position
03)
High-limit
display value
1-13
gradient
INbH
correction
Exponent of
1-14
INB
INbE
01) Displays at AC voltage or AC current model only.
02) Low-limit display value deviation correction range is within -99 to 99 for D
03) Display range is variable according to decimal point position.
Dot
Display range
-1999 to 9999
0
-199.9 to 999.9
)0
-19.99 to 99.99
)00
-1.999 to 9.999
)000
Parameter 1
→
[MODE] 3 sec
group
Parameter 2
→
[MODE] 3 sec
group
Parameter 0
→
[MODE] 3 sec
group
→
Zero adjustment
Auto
Reset
→
[MODE]
Defaults Setting range
[DC voltage model], [AC voltage model]
• Refer to Input Range and Display Range
500V
[DC current model], [AC current model]
• Refer to Input Range and Display Range
5A
STND: standard, SCAL: scale, FREQ:
frequency
01)
STND
[AC voltage model], [AC current model]
T.RMS: True RMS, A.RMS: Average RMS,
AVG
A
+ A
+ ··· + A
2
2
• True RMS =
1
2
n
A
+ A
+ ··· + A
tRMS
• Average RMS =
1
2
n
× Waveform rate
(n = number of display values per cycle,
A = display value)
[DC voltage model], [AC voltage model]
Max. value of display range
50)0
[DC current model], [AC current model]
Max. value of display range
%000
!000 0.100 to 5.000 %
00 -99 to 99
[DC voltage model], [AC voltage model]
0, 0.0, 0.00, 0.000
)0
[DC current model], [AC current model]
0, 0.0, 0.00, 0.000
)000
Display value against max. measurement input*
Display value against min. measurement input*
!000 0.100 to 5.000 %
00 w-99 to 99
[AC voltage model]
0, 0.0, 0.00, 0.000
)0
[AC current model]
0, 0.0, 0.00, 0.000
)000
!000 0.100 to 9.999
10-0 10-0: 10
, 10-1: 10
, 10-2: 10
0
-1
, D
digit regardless of decimal point position.
0
-1
Frequency measurement range
1 to 9999 Hz
0.1 to 999.9 Hz
0.10 to 99.99 Hz
0.100 to 9.999 Hz
→
→
RUN
→
→
→
Display
condition
-
-
-
1-2
2
Display
n
method:
STND,
n
SCAL
1-2
Display
method:
STND
1-2
Display
method:
SCAL
&
* 1-7
Decimal
point
position:
0.0, 0.00,
0.000
1-2
Display
method:
FREQ
, 10 1: 10
-2
1