PSAN Series
Hysteresis mode [ fOUT
Press
If forced output control mode
is selected, pressure value is
displayed only.
(No output will be provided.)
Control output 1 OFF
Control output 2 OFF
※ If there is no additional key operation within 60 sec while setting, it
is returned to Run mode (Except for force output mode). Previously
set values are remained.
※ In case of changing output operation mode, no preset values will be
initialized. Instead, previous output operation settings will become
the preset values.
※ When using the forced output function, Hold/Auto shift function is
not available to use in Hold/Auto shift model.
※ When changing pressure display unit, resolution, and Hold Auto
shift input function, preset values will be initialized as shown the
next table. (When changing pressure display unit, preset value will
be automatically switched to changed pressure unit.)
High peak/Low peak function and Auto shift reference pressure check/change
Press
for 3 sec.
Press
Key for
3 sec in RUN mode.
※ 1: Displayed only when D-IN is set to SHFT(PSAN-
※ If there is no Auto shift input, "0" will be displayed.(Refer to E-14 page for more details.)
E-12
fOUT ]
Key
Present pressure value and
will flash in turn every 0.5 sec.
Control output 1 OFF
Control output 2 OFF
Key
Press
for 3 sec.
Press
keys over 1sec.
Remove the
retained minimum
pressure value.
Retained maximum
pressure value will
flash every 0.5 sec.
" HHHH" will flash if retained
maximum pressure value
is above the upper limit of
rated pressure.
(For negative pressure type,
" LLLL" will flash)
Press
Key
● Factory default
Negative
Output
pressure
mode
0.0~-101.3
ST1 :-50.0
HYS1 :0.0
HYS.M
ST2 :-50.0
HYS2 :0.0
LO-1 :0.0
HI-1 :-50.0
WIN
LO-2 :0.0
HI-2 :-50.0
ST1 :-50.0
HYS1 :0.0
HY-W
LOW :0.0
HIGH :-50.0
ST1 :0.0
AUTO
ST2 :-50.0
SET :-25.0
Press
Key
Press
+
Press
keys over 1sec.
Remove the
retained minimum
pressure value.
Retained minimum
pressure value will
flash every 0.5 sec.
" LLLL" will flash if retained
minimum pressure value
exceeds low-limit of rated
pressure.
For negative pressure type,
" HHHH" will flash)
H-
models only)
Standard
Standard
pressure
pressure
0.0~100.0
0~1,000
ST1 :50.0
ST1 :500
HYS1 :0.0
HYS 1:0
ST2 :50.0
ST2 :500
HYS2 :0.0
HYS2 :0
LO- 1:0.0
LO-1 :0
HI-1 :50.0
HI-1 :500
LO-2 :0.0
LO-2 :0
HI-2 :50.0
HI-2 :500
ST1 :50.0
ST1 :500
HYS 1:0.0
HYS 1:0
LOW :0.0
LOW :0
HIGH :50.0
HIGH :500
ST1 :0.0
ST1 :0
ST2 :50.0
ST2 :500
SET :25.0
SET :250
It will be returned to RUN
+
keys over 1sec.
mode after previously
set Auto shift reference
Press
Key
pressure is removed.
Key
+
Auto shift reference
pressure value will
flash every 0.5 sec.
Press
or
key
to select set value
(unit: kPa)
Compound
pressure
-101.3~100.0
ST1 :50.0
HYS1 :-50.0
ST2 :50.0
HYS2 :-50.0
LO-1 :-50.0
HI-1 :50.0
LO-2 :-50.0
HI-2 :50.0
ST1 :50.0
HYS1 :-50.0
LOW :-50.0
HIGH :50.0
ST1 :-50.0
ST2 :50.0
SET :0.0
※ 1