Sfoglia online o scarica il pdf Manuale di avvio rapido per Automobile Accessories DC Power Solutions B-COOL12000WMB 24V. DC Power Solutions B-COOL12000WMB 24V 14. Split unit

Installation Instructions For B-COOL12000SPU
MODEL #
B-COOL12000WMB 12V & 24V
Keep in mind the outside machine weighs 24 Kgs or 53lbs,
Place the Air conditioner in the desired position.
Select the installation position and mark spot where to
Use a pull riveter to fix the pull nut at the marked hole.
Install the shock absorption washer.
Attach the inside (evaporator) mounting plate
Now attach the evaporator - it weighs 6.2Kgs or 13.6lbs.
Cut a hole(50mm) to connect internal and external
Connect the Pipe/ Hose provided.
Vacuum and Re-Fill the Freon for 30-45 minutes.
(R134a 650-700g).
Run the power cables to the main battery or auxiliary
batteries.
Check the polarity before installing the cables
Connect the power wire to the automotive battery.
9
Get someone to help you.
punch the holes.
Install the expansion Valve.
Units.
Enjoy Cool Air.