METAL DUCTWORK INSTALLATION
1
2
1. Locate suitable area of
2. Cut away insulation to expose metal duct (if
duct for installation.
needed).
3
4
3. Mark location for 3.5" opening using either the
4. Cut hole in duct using 3.5" hole saw.
mounting plate or included template.
ALTERNATIVE CUTTING METHOD
b
a
b. Drill 4 holes where marked.
a. Using template, mark 4 holes on duct.
c
c. Cut between holes using tin snips.