WIRING ThE UNIT

Note: Disconnect power at the breaker or fuse panel before servicing unit.
WARNING: Hard wiring unit into HVAC system should be done by a
licensed HVAC installer or qualified electrical contractor only.
1
1. Connect wires coming from the activTek INDUCT 5000/INDUCT 10000
unit to the fan relay as follows:
All units come standard with a blunt cord.
NOTE:
120 Volt Unit:
Black Wire
White Wire
Green Wire
2
2. Connect the unit to the load side of the proper fan relay.
3
3. Be sure to ground the ballast by securing the unit to
the metal surface of the AC unit or power box.
4
4. Check indicator light for proper operation with fan on.
220 Volt Unit:
L1
Black Wire
White Wire
Neutral
Green Wire
Ground
International Unit:
L1
Brown Wire
Blue Wire
L2
Green with
Ground
Yellow Stripe
L1
Neutral
Ground