Autonics ARD-DO08N-4S Manuale

Sfoglia online o scarica il pdf Manuale per Sistemi I/O Autonics ARD-DO08N-4S. Autonics ARD-DO08N-4S 8. Devicenet digital remote i/o
Anche per Autonics ARD-DO08N-4S: Manuale (8 pagine)

Autonics ARD-DO08N-4S Manuale
ARD-D Series
DeviceNet Digital Remote I/O
Features
● Automatic communication speed recognition
: Enables to recognize communication speed automatically when connecting
with master
● Network Voltage monitoring
: If PV is lower than SV, enables to receive error flag for network power
monitoring as Explicit message.
● Additional expansion units
- Standard terminal block type: Connectable up to 3 expansion units
- Sensor connector type: Connectable up to 7 expansion units
- Expandable I/O points up to max. 64 points for Standard terminal type,
sensor connector type
● Reading the number of expansion units
: Reads the number of connected expansion units
● Reading model name: Reads the connected model name of connected
units(sensor connector type)
● Reading the unit specifications: Reads the specifications of connected units
Please read "Caution for your safety" in operation
manual before using.
Ordering Information
AR
D
D
Digital/Analog
Network
Item
※ 1: Sensor connector type(ARD-
※ 2: Sensor connector(CNE-P04- ) is sold separately. It is compatible with e-CON connector.
※ 3: It is only for an expansion unit of sensor connector type.
※ 4: It is only for an expansion unit of standard terminal block type.
※ 5: For ARD-A Series as analog type, refer to S-13 page.
Model
Model
Terminal type
Basic unit
ARD-DI08A
ARD-DI16N
ARD-DI16P
ARD-DO08R
Standard
terminal block
ARD-DO08S
type
ARD-DO16N
ARD-DO16P
ARD-DX16N
ARD-DX16P
ARD-DI08N-4S
Sensor
ARD-DI08P-4S
connector
ARD-DO08N-4S
type
ARD-DO08P-4S
C-142
I
08
A
E
4S
Structure
I/O specification
I/O point
I/O type
-4S) model is only for NPN, PNP I/O specifications.
Specification
Expansion unit
ARD-DI08AE
75-250VAC input 8-point(13mA/point)
ARD-DI16NE
10-28VDC NPN input 16-point(10mA/point)
ARD-DI16PE
10-28VDC PNP input 16-point(10mA/point)
ARD-DO08RE
Relay output 8-point(2A/point), Life cycle of contact: 100,000 times
ARD-DO08SE
SSR output 8-point(1A/point)
ARD-DO16NE
NPN output 16-point(0.5A/point)
ARD-DO16PE
PNP output 16-point(0.5A/point)
ARD-DX16NE
10-28VDC NPN input 8-point(10mA/point), NPN output 8-point(0.5A/point)
ARD-DX16PE
10-28VDC PNP input 8-point(10mA/point), PNP output 8-point(0.5A/point)
ARX-DI08N-4S
10-28VDC NPN input 8-point(10mA/point)
ARX-DI08P-4S
10-28VDC PNP input 8-point(10mA/point)
ARX-DO08N-4S
NPN output 8-point(0.3A/point)
ARX-DO08P-4S
PNP output 8-point(0.3A/point)
Terminal
※ 2
block
No-mark
Standard terminal block type
4S
Sensor connector type(4pin)
No-mark
Basic unit
※ 4
E
Expansion unit
A
AC voltage
※ 1
N
NPN open collector
P
PNP open collector
08
8 points type
16
16 points type
I
Input type
O
Output type
X
I/O mixed type
D
Digital type
※ 5
A
Analog type
D
Basic unit(DeviceNet type)
※ 3
X
Expansion unit(use in DeviceNet/Modbus)
AR
Autonics Remote I/O
Standard terminal
block type
Sensor connector type
R
Relay
S
SSR