GALAXY SPAS PH-015/R1U Libro tecnico - Pagina 10

Sfoglia online o scarica il pdf Libro tecnico per Pompa di calore GALAXY SPAS PH-015/R1U. GALAXY SPAS PH-015/R1U 12.

GALAXY SPAS PH-015/R1U Libro tecnico

Operating modes

The operating mode can be changed through the spa user interface.
Six different operating modes are available:
1) Eco Heat (EcoH)
2) Smart Heat (HEAT)
3) Cool (COOL)
4) Eco Auto (AUTO)
5) Smart Auto (SMRT)
6) Electric (ELEC)
Eco Heat (EcoH)
In this mode, the Heat pump is used as the unique source
of heating. The heating element is kept off and the Heat
pump is not used to cool the water should its temperature
rise above the current set point.
Smart Heat (HEAT)
This mode uses the Heat pump as the main heating
source. The heating element is turned on only if there is
a large temperature difference between the water and the
set point or if the ambient temperature gets too low. The
Heat pump is not used to cool the water in this mode.
Cool (COOL)
This mode uses the Heat pump in cooling mode only.
The Heat pump is not used as a heating source and the
heating element is never activated.
Freeze Protection
In cold weather, if it becomes impossible for the Heat pump to keep the water temperature above freezing point, the
help of the heating element might be required even if its use should be prohibited by the operating mode or conditions.
At any time, if the water temperature drops too close to the freezing point, the operating mode will be switched
temporarily to "Smart Heat" and the system will heat until the minimum allowed set point has been reached before
reverting to its previous operating mode and resume normal operation.
Three minutes waiting time
In any circumstances, when the Heat pump is shut down, please be aware that there is forced waiting time of three
minutes before the Heat pump can operate again. This is so to prevent damage to the equipment. For example, if the
operating mode has been changed from Cold to Hot succeeding an increase of the setpoint, the Heat pump will be
allowed to start only after a delay of three minutes.
9
Eco Auto (AUTO)
This mode borrows functionality from both Eco Heat
and Cool modes and has the ability to select the proper
Heat or Cool mode automatically according to the water
temperature. The heating element is never activated in
this mode.
Smart Auto (SMRT)
This mode borrows functionality from both Smart Heat
and Cool modes and has the ability to select the proper
Heat or Cool mode automatically according to the water
temperature. The heating element is activated only if there
is a large temperature difference between the water and
the set point or if the ambient temperature gets too low.
Electric (ELEC)
This mode keeps the heat pump off and uses only the
heating element to regulate water temperature.