Autopilot ECLIPSE F90 Manuale d'uso - Pagina 8

Sfoglia online o scarica il pdf Manuale d'uso per Controllore Autopilot ECLIPSE F90. Autopilot ECLIPSE F90 12. Master environmental controller

Autopilot ECLIPSE F90 Manuale d'uso
setting if using an exhaust fan for both temperature and humidity control.
UNLOCK: Each device is controlled independently. Use this setting if using different devices to
control Cooling and Humidity.

HUMIDITY SETTINGS

Click each knob (DAY HUM and NIGHT HUM) and turn to set your desired day humidity and night
humidity settings. Click again to confirm the settings.

HUMIDITY DEADBAND (HYSTERESIS)

This unit has a 5% relative humidity non-adjustable deadband.

HUMIDITY MIN/MAX RECALL

Click the DAY HUM and NIGHT HUM knobs simultaneously to recall humidity min/max temp record.

HUMIDITY MODE SWITCH

This switch selects either dehumidifier or humidifier control.

TEMP DEADBAND OPTIONS

2/4/6°F (1/2/3°C)

TEMP DEADBAND SETTING

Click each knob and turn to set the PPM target and deadband (hysteresis). Click again to confirm the
setting.

CO 2 MODE

PPM UP: Increases the CO
Fuzzy Logic: Increases the CO
PPM DOWN: Decreases the CO

HIGH TEMPERATURE PROTECTION

If when using a CO
2
limit, the ECLIPSE F90 will deactivate the CO
reached the setpoint yet. The CO
to 10°F/5°C less than the high limit.

HOW TO SET HIGH TEMP LIMIT

For daytime high limit temperature setting, click and hold the DAY TEMP knob for 3 seconds. The
display will flash "H (XX)" (Fig. 3) repeatedly. Turn the knob to change the setting. Click it again to
save the setting.
NOTE: To set night temps, the procedure is the same as described above for day temps, but the
NIGHT TEMP knob is used.
PPM when using a (gas) CO
2
PPM when using a compressed CO
2
PPM using a fan.
2
generator with this controller the environmental temperature exceeds the set
generator will become active again when the temperature returns
2
generator.
2
outlet, regardless of whether the CO
2
8
system.
2
PPM level has
2