Autoplugin RCP-FM Manuale d'uso - Pagina 12

Sfoglia online o scarica il pdf Manuale d'uso per Moduli GSM/GPRS Autoplugin RCP-FM. Autoplugin RCP-FM 12.

3
Battery low
4
Time limits
exceeded
5
Unsuccess-
ful start
6
Operation
cycle too
short
8
CAN-bus
error
9
Settings
error
11
Heater no
connection

Glossary

CAN - Control Area Network (digital network for data transfer in vehicles)
RCP - Remote Control Plug-in (electronic module for the heater remote control)
CIP - Combined Instrument Panel
BHM or Boost Heat Mode – operational mode of the heater, when it operates
together with the engine to help the engine and the interior warm up more
quickly.
© Autoplugin ES
12
The module has
determined that battery
voltage at heater startup
or during heater
operation is below of
specified by settings 4.1
or 4.2
Time limit for
autonomous operation of
the heater has achieved
(with active setting 2.1.2
- 2.1.9)
The heater switched off
spontaneously at startup
The heater was switched
off spontaneously with
operating time of less
than 20 minutes
There is a problem with
connection of the
module to the CAN-bus
Settings have been
incorrectly stored in
RCP memory
The heater is unplugged
from CAN-bus or is out
of order
Charge battery with special
charger (or start engine to
charge) or cancel 4.1/4.2
module's settings
Run the engine. It is
recommended to make trips
between heater operation cycles
longer than heater operation
cycles
Make diagnostics of the heater
if the error appears again
Make diagnostics of the heater
if the error appears again
Check for the module's cables
connection
Reset the settings (8.1.1),
readjust RCP
Make diagnostics of the heater
www.autoplugin.ru