Dynatech QUASAR T25 A3 Manuale di istruzioni per l'uso e la manutenzione - Pagina 8
Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso e la manutenzione per Controllore Dynatech QUASAR T25 A3. Dynatech QUASAR T25 A3 8. Ucm unit
Anche per Dynatech QUASAR T25 A3: Manuale di istruzioni per l'uso e la manutenzione (9 pagine)
Instruction Manual: D-Box + QUASAR T25 A3 + ASG UD
Date: 18-12-17
Revision: 02
Under normal conditions, where no UCM is detected, the governor's parking system 24V coil is energised, thus
preventing the parking system from interlocking the QUASAR T25 A3 governor. Therefore, the system operates in
positive safety.
4 ASSEMBLY AND MAINTENANCE
D-Box:
Only specialised and duly trained staff must carry out the assembly, electrical wiring and start-up. For further
information on assembly, the characteristics of the electrical wiring and wiring diagrams, please refer to the D-Box's
manual for use and maintenance.
QUASAR T25 A3 + ASG UD:
The QUASAR T25 A3 Beta governor will be assembled and adjusted in accordance with the QUASAR T25 overspeed
governor's manual for use and maintenance.
Please check that the governor rope is correctly positioned and that the parking system is correctly operating, by
checking that the 24V coil is energised in normal operation.
Please check the distance from the safety gear brake shoe to the guide rail. Please also check that the governor
rope is correctly secured and operating onto the T-25 steering mechanism's handle.
Please check periodically that no damage has occurred, which may put the normal use of the lift at a risk. The safety
gear's friction components can be replaced. Visual inspection is enough.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the customer
area in Dynatech's website in order to consult the full manual; http://customers.dynatech-elevation.com/
Cod: DYN62-3.02
Figure 4: ASG UD Mechanism Operation
6