2HEAT RF-Optima W R2 PLUS Manuale di avvio rapido - Pagina 3

Sfoglia online o scarica il pdf Manuale di avvio rapido per Termostato 2HEAT RF-Optima W R2 PLUS. 2HEAT RF-Optima W R2 PLUS 4.

2HEAT RF-Optima W R2 PLUS Manuale di avvio rapido
Default Setting:
Period
12345(Mon.~Fri.)
6(Sat.)
7(Sun.)
Parameter Setting
Turn thermostat off, press and hold SET button and + button for 6s to enter parameter setting. Each press of SET button
will go to next item setting. Adjust the value by pressing + or – button.
Menu
01
Temp. calibration for internal sensor
02
Set Point Max.
03
Set Point Min.
04
Sensor Select
05
Frost Protection Temp.
06
Floor Temp. Display
08
High temp protection
09
Dead zone
10
Display
11
Child Lock
12
Open window detect function
13
OWD Detect Time
14
OWD Drop temp. select
(within detect time)
15
OWD Delay time select
(Return to previous working status)
17
Factory reset
18
Software version
LVS vloerverwarming BV | Flemingstraat 9 | 1704SL Heerhugowaard | NETHERLANDS | T: +31 (0)72 5400560 | [email protected]
RF-Optima W R2 PLUS thermostat
1
Time
Temp
Time
7:00
22℃
8:30
8:00
22℃
8:30
8:00
22℃
8:30
Description
2
3
Temp
Time
Temp
19℃
17:00
22℃
22℃
17:00
22℃
22℃
17:00
22℃
Range
-8 ℃ ~8 ℃
5 ℃ ~35℃
5 ℃ ~35℃
0: Internal sensor
1: External sensor
2:Internal & External sensor
5 ℃ ~15℃
Read Only
20°C ~ 80°C
0~3℃
0: Room temp.
1: SET temp.
0: Disable
1: Enable
1: Enable 0: Disable
2~30mins
2.3.4'C
10~60min
0: No
1: Yes, and then press
On/off button for 5s,wait until
thermostat restart
3206
4
Time
Temp
22:00
19℃
22:00
19℃
22:00
19℃
Default Value
0℃
35 ℃
5 ℃
2
5 ℃
32 ℃
0℃
0
0
0
15mins
2 'C
30mins
0