Technical Specifications

Technical Specifications
Routine maintenance
Cleaning
Power required
Environmental
Mounting height

Approvals and Standards

Not applicable for this reader
This reader should only be cleaned with a clean, lint
free, damp cloth
Voltage: 9Vdc - 16Vdc
Current: 40mA (at 16Vdc)
70mA (at 9Vdc)
The current will increase momentarily during a card
read, beeper and LED activity: 120mA (at 12Vdc)
Operating temperature: -30°C to +70°C
Note: Direct sunlight may increase the internal reader
temperature above the ambient temperature level
Humidity: 95% non-condensing
Environmental Protection: IP67*
* Pending final test results
1.1m (3.6ft) to centre
This product complies with the environmental regulations for the
Restriction of Hazardous Substances in electrical and electronic
equipment (RoHS). The RoHS directive prohibits the use of
electronic equipment containing certain hazardous substances
in the European Union.
This symbol on the product or its packaging indicates that this
product must not be disposed of with other waste. Instead, it
is your responsibility to dispose of your waste equipment by
handing it over to a designated collection point for the recycling
of waste electrical and electronic equipment. The separate
collection and recycling of your waste equipment at the time
of disposal will help conserve natural resources and ensure
that it is recycled in a manner that protects human health and
the environment. For more information about where you can
drop off your waste equipment for recycling, please contact
your local city recycling office or the dealer from whom you
purchased the product.
ACN 002 132 943
Installation Note | Gallagher T10 Mifare Reader
Part Number: 3E2453 R1 | 9