DCS 36 inch Manuale di installazione - Pagina 9

Sfoglia online o scarica il pdf Manuale di installazione per Gamme DCS 36 inch. DCS 36 inch 15.

Always disconnec{ electric supply cord from the
wall outlet or serviice disconnect before servicing
this appliance.
-See Fig 7
The open top grates should be level and not rock.
They are supported in three places by leveling
screws and should be adjusted after final place-
ment of the range.
The grill and griddle sections are fastened in
place at the front with screws. They are designed
to be stationary and not meant to be removed for
cleaning.
The griddle has two leveling screws beneath the
rear flue cover which can be used to adjust the
griddle to the desired slope. The center screw is
for shipping and should be removed.
Observe all governing codes and ordinances when
grounding, in the absence of which, observe
National Electrical Code ANSI/NFPA No. 70-
1990.
RECOMMENDED GROUNDING
METHOD
This appliance is j~ctory equipped with a power
supply cord with a three-prong grounding plug
(with polarized pa.rallel blades). It must be
plugged into a ma.ting grounding, type receptacle,
connected to a correctly polarized 120 Volt cir-
cuit. If the circuil: does not have a grounding
type receptacle, it is the responsibility and obliga-
tion of the installt~r or used to have the existing
receptacle change~i to a properly grounded and
polarized receptac:le in accordance with all applic-
able local codes and ordinances by a qualified
electrician. In th(~ absence of local codes and
ordinances the receptacle replacement shall be in
accordance with the National Electrical Code.
THE THIRD
GROUND
PRONG SHOULD
NOT, UNDER ANY CIRCUMSTANCES,
BE
CUT OR REMOVED
(See Fig. 11).
FIG. 11
Three "'-
Prong
Plug
ff
'"
Verify the type of gas supplied to the location
The range is shipped from the factory set up and
adjusted for natural gas. The unit can be readily
converted to LP gas. After LP conversion, burner
adjustment may be necessary.
POWER REQUIREMENTS
120 VAC, 60 Hz., single phase.
DCS-RG-304: 4 Amp. Max.
DCS-RG-36: 7 Amp. Max.
DCS-RG-48: 13 Amp. Max
(Use 15 Amp. Circuit)
NATURAL GAS REQUIREMENTS
Connection:
1/~~" N.RT. Minimum
5/8" dia,
flex line. Pressure: 6" to 14" W.C.