Dyness A48100 Manuale di avvio rapido - Pagina 3
Sfoglia online o scarica il pdf Manuale di avvio rapido per Pacco batteria Dyness A48100. Dyness A48100 8. Battery and solis setup
No matter how many inverters and how many batteries are in
parallel,it is always the master battery communicates to the master
inverter.
1.Dyness A48100 connect with Inverter
INV-BAT: From the master CAN IN to the
inverter CAN port;
BAT-BAT: From the master CAN OUT to the
salve1 CAN IN, the salve1 can OUT to the
salve2 CAN IN...
Master 0010
Salve 0000