CAUTION: For General Ventilation Use Only. Do Not Use To Exhaust Hazardous or Explosive Material and Vapors.
CAUTION: This unit has an unguarded impeller. Do not use in locations readily accessible to people or animals.
WEAR HAND PROTECTION AND STAY CLEAR OF SHARP EDGES! The compactness and adaptability of the
model PSD blower permits easy installation. The units are shipped fully assembled and can be mounted at any
angle. For mounting suggestions see pages 3 & 4. Because this unit has rotating parts, safety precautions should
be exercised during all phases of installation, operation and maintenance. Remove unit from package and inspect
before installation. If damaged, report damage to carrier. DO NOT operate this unit with visible damage to the blower
or impeller assembly. Screen guards must be installed when blower will be within reach of personnel, within (7) feet
of the working area, or when advisable for safety.
WARNING! DO NOT CONNECT POWER SUPPLY until blower is completely installed.
Make sure electrical service to the blower is locked "OFF" position.
Check voltage at blower to see if it corresponds to the motor name plate. Installation work and electrical wiring
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated
construction.
Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel
burning equipment, (e.g., gas water heater, gas furnace) to prevent back drafting.
Follow the heating equipment manufacturer's guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted
blowers must always be vented to the outdoors.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be
connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circui
NEVER place a switch where it can be reached from a tub or shower.
All units are suitable for use with solid-state speed control.
WARNING! TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) or fuel burning
equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards
such as those published by the National Fire Pr otection Association (NFPA) and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
Duct blowers must always be vented to the outdoors.
CopperSmith, Remote Blower Installation Instructions (All Models), Revised 09-18-16
t.