SAFETY PRECAUTIONS
Always disconnect the power supply
-
before installing or making modifications to the device.
.
- The fitting and handling of these devices must be carried out by
.
- The wiring must run at least 40 cm. away from any other wiring.
- Do not overtighten the screws on the connector.
- Install the monitor in a dry protected location free from the risk of dripping or splashing water.
- Do not place in humid, dusty or smoky locations, or near sources of heat.
- Before connecting the device to the mains, check the connections between the door panel, power
supply, distributors and monitors.
- Always follow the instructions contained in this manual.
CHARACTERISTICS
( )
*
- Hands-free monitor.
- 4,3
" TFT c
olo r
u screen
.
.
-
Function push buttons
for access and selection of menu function.
- Monitor
with simple installation (non-polarised 2 wires bus)
.User
-
User menu
.
.
-
Installer menu
.
.
-
Image and communication settings menu
.
.
-
Output auxiliary call repeater (max.
50mA/12V ).
.
- "HZ" input for calls from apartment front door
button "HZ" activated at the same time (with system and monitors in standby).
.
- Push buttons for door release 1 and 2.
.
-
Notification l
eds.
.
-
Configuration switches
.
SYSTEM OPERATION
( )
*
- To make a call, the visitor must press the button of the apartment; an audible sound indicates that the call
is being made and
door panel
LED
will turn on. If vocal synthesis is enabled, a 'Call is in progress'
message appears indicating that a call is being made. At this moment, the apartment's monitors receive
the call. If another apartment is called by mistake, press the button for the correct apartment and the first
call will be cancelled.
.
- Upon receiving the call, the image will appear on the screen of the master monitor (and slave 1, if it
exists) without the visitor knowing and icon
image from slave monitors 2 or 3, press
one of the buttons of the monitor to display the image
call is not answered within 45 seconds,
door panel
.
-
To establish communication, press
the button below
panel LED
will turn off and the led
will
turn on
.
-
Co
mmunication
will last for 90 seconds or until
is
pressed. When communication ends,
door panel
vocal synthesis is enabled, a 'Communication is finished' message will indicate that the call is over.
.
-
To open door
or
of the door panel
,
press the
1
2
screen
during the call or communication processes: one press will activate the lock release for
seconds and
door panel
LED
will also turn on for seconds. If vocal synthesis is enabled, a 'Door
open' message will be indicated on the door panel.
.
-
Detailed operation
and configuration
of the monitor
INSTALA
TION OF THE
MONITOR
( )
*
( )
For more information, see
"TART 4/G2+
user manual
*
https://doc.golmar.es/search/manual/50122527
authorised personnel
.
.
dc
Important:
.
Up to monitors/ apartments with push
6
displayed on the screen will blink green. To view the
LED
will turn off and the system will become free.
off-the-hook icon
sh wn on
o
the screen. Door
.
the button below
on-the-hook icon
shown on the screen
LED
will turn off and the system will become free. If
button below the
corresponding icon
displayed
3
, see "TART /G2+" user manual
4
.
(code 50122527)".
2
ART /G2+
4
MONITOR
DESCRIP
TION
MONITOR
( )
*
A
B
C
H
I
SA
GND
J
HZ
HZ
BUS
BUS
SA
GND
HZ
HZ
BUS
BUS
H
Monitor address (code) setup:
( )
*
Dip1 Dip7:
-
Sets the monitor address (addresses to
The switches set to OFF have a zero value. The values of the switches set to ON are shown in the table below. The
monitor code is the sum of the values of the switches set to ON.
Important: Apartment 1 (Dip1 to ON & Dip2-Dip to OFF).
Important: Apartment 2 (Dip1 - Dip to OFF).
1 8
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitors where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip 8 a ON
ON
. If the
1
2
3
4
5
6
7
8
Not : e To define whether the monitor is master or slave, e
"0551" Slave
1,
"0552" Slave or "0553" Slave ).
Dip1 to Dip : 7 These assign the address of the monitor to call button on the door panel.
Switches - must remain in the OFF position.
2 7
Apartment 1
on the
1 ( )
ON
3
1
2
3
4
5
6
7
8
is
Dip8: This activates the end-of-line resistance in the ON position. Activate it in monitor where the bus cable ends.
Deactivate it only in intermediate monitors.
Dip 8 a ON
ON
1
2
3
4
5
6
7
8
Not : e To define whether the monitor is master or slave, e
"0551" Slave
1,
"0552" Slave or "0553" Slave ).
( )
For more information, see
*
https://doc.golmar.es/search/manual/50122527
EN
A.
Speaker
.
B. Function buttons, access and selection of menu functions.
The function of each button is shown on the monitor screen with an
icon located just above each button
*
Press to access 'Doctor mode' function (standby monitor):
D
- With the special code '0441' (Doctor mode) already entered (see
"TART 4/G2+" manual"), press the button for 5 sec. to activate/
deactivate the function.
- The push button led
'Doctor mode' is activated and it will turn off if the function is
deactivated.
G
*
Press to acces the recordings menu (standby monitor):
- The push button led
E
photo/video is pending viewing. Pressing will access the
recordings menu.
F
C.
Monitor status
LED:
Yellow ON: Standby without notification.
Red ON: "Do not disturb" Mode a tivated.
H
D. 4.3" TFT colour screen.
E.
Microphone
.
F.
Raised dots for the visually impaired
In call
/communication
:
Above this raised dot is the 'Start/ nd communication' button.
MADE IN CHINA
Above these raised dots is the 'Door opening' button.
128
codes
G. Micro SD card slot (not included).
DIP 1 to 7
Monitor
address
Type: MicroSD Class 10 from 4
DIP 8
H. Wall mounting connector fixing (x4).
EOL
resistor
OFF = 0
I.
ON = 1
Configuration switches.
H
J.
Installation terminals
.
Building / Villa (Nexa Door Panel)
1
1 8
2
).
Table of values
7
Switch number:
1 2 3 4 5
7
Value when ON
:1 2 4 8 16 32 64
Dip 8 a OFF
ON
1
2
3
4
5
6
7
8
ntering the corresponding "Special code" (
2
3
Villa (Soul Door Panel)
*
Apartment 1 (Dip1 to ON) ART
4
G2+ monitor with V.0 and later.
1 ( )
Dip 8 a OFF
ON
1
2
3
4
5
6
7
8
ntering the corresponding "Special code" (
2
3
"TART 4/G2+
user manual
(code 50122527)".
3
(see "TART 4/G2+" manual)
.
will blink in white color if the function
will blink in white color indicating that a
c
people.
E
GB
to 128
GB
.
ON
6
7
1
2
3
4
5
6
7
8
Example: 0+ 0+4+0+ 16+
0+0
= 20
: "0550" Master,
*
3
Kit Soul / Art
4
manual
: "0550" Master,