CORA CS1060 Manuale d'uso - Pagina 5
Sfoglia online o scarica il pdf Manuale d'uso per Regolatore di temperatura CORA CS1060. CORA CS1060 18. Temperature & humidity sensor
User
Interface
Set Button
The CS1060 user interface consists of the LED status indicators (Figure 2) and the set button
located on the underside of the device. Pressing the button once will uplink current temperature
and humidity measurements and indicate the current network status discussed previously.
Figure 3 – Performing Network or Factory Reset
Holding the button will perform a network or factory reset:
⧫
Network Reset
– Press and hold the SET button for 10 seconds, but less than 25, then
release. The device will reset all LoRaWAN Settings, which does not affect device operation
or configuration. Following reboot, a reset event uplink (confirmed) will be sent upon
rejoining the LoRaWAN network.
Factory Reset
– Press and hold the SET button for > 25 seconds, then release. The device
⧫
will reset all parameters to factory defaults. Following reboot, a Factory Reset event uplink
(confirmed) will be sent upon rejoining the LoRaWAN network.
CS1060 Temperature & Humidity Sensor – User Guide
Page 5