TROUBLESHOOTING
PROBLEM
Taps are dripping water
Water is not flowing from tap
Handle is loose
© Galvin Engineering Pty Ltd
Temp. indicator
5. Testing
Check the operation of the unit and inspect for any leaks.
CAUSE
Ceramic discs are worn or damaged
Tap seat is damaged
Water is turned off
Aerator or flow regulator is blocked by
debris
Obstruction on spout
Screw has come loose
Version 1, 7 July 2023, Page 4 of 5
RECTIFICATION
Remove and inspect SBA.
Remove debris and/or
replace SBA if damaged.
Refurbish tap seat using a
reseating tool.
Turn water on
Remove aerator and/or flow
regulator from tap and remove
debris. Install an inline strainer.
Check if there are obstructions
hindering the water flow in the
spout and take it out.
Tighten handle screw