Galvin Engineering WaterMark 46730 Istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione per Prodotto idraulico Galvin Engineering WaterMark 46730. Galvin Engineering WaterMark 46730 4. Bs lever action sba

Galvin Engineering WaterMark 46730 Istruzioni per l'installazione
Product Installation Guidelines
INSTALLATION
IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and
in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply
conditions must also comply to the applicable national and/or state standards. Failing to comply with these
provisions shall void the product warranty and may affect the performance of the product.
Note: Tapware body used as an example only. SBAs can fit on different kinds of Ezy-Wash bodies.
1. Remove Handle
Prior to installation turn off the water supply.
Remove the handle assembly. To prevent
damage, carefully pry off plastic indicator from
the handle. (Use a small flat bladed screwdriver
if necessary).
3. Refit new head
-
Refit new head into tap body.
Note: do not tighten cartridge using the
handle as this will result in damage to the
cartridge
© Galvin Engineering Pty Ltd
2. Replace spindle assembly
New ceramic head
New head
4. Reassemble Handle
-
-
Unscrew the head part from the threaded sleeve
using a 17mm spanner.
Check seat inside tap body for pitting or damage.
Re-seat if necessary
Refit adaptor and reassemble handle by
reversing step 1.
When installation is complete, slowly open
water supply and inspect for leaks.
Document Number: 001.00.70.13
Version 1, 4 November 2022, Page 2 of 4