MAINTENANCE
FILTER CLEANING INSTRUCTIONS
This faucet is provided with a stainless-steel filter to prevent foreign particles entering the tap. If the water flow
has decreased, this may be because the filter is clogged. The filter can be cleaned as follows:
1. Disassemble:
−
Shut-off the water supply to the valve.
−
Release the set screw at the faucet body by using the 2.5 mm Allen Key.
−
Disassemble the faucet's body from the base.
2. Clean filter:
−
Disassemble the filter from the base.
−
Wash the filter under running water.
−
Fit the filter.
AERATOR CLEANING INSTRUCTIONS
1.
Disassemble and Clean
−
Using an adjustable spanner, unscrew the
aerator holder.
−
Wash the aerator under running water.
CARE AND CLEANING OF CHROME AND SPECIAL FINISHES
DO NOT use steel wool or cleansing agents containing alcohol, acid, abrasives, or the like. Use of any
prohibited cleaning or maintenance products or substances could damage the surface of the faucet. For
surface cleaning of faucet, use ONLY soap and water, then wipe dry with clean cloth or towel. When cleaning
bathroom tile, the faucets should be protected from any splattering of harsh cleansers.
:
Version 2, 16
3. Assemble:
−
Slide the flange and the faucet onto the inlet tail.
−
Mount the faucet body onto the inlet tail. Ensure
the sensor is aligned facing down. Secure the
body with M5 grub screw using the supplied
Allen key.
2. Assemble:
−
Once cleaned, fit cleaned aerator back into the
holder.
−
Using the adjustable spanner, tighten the aerator
holder back into the body.
th
March 2021, Page 7 of 9