AGS Mini Merlin CH4CO Manuale d'uso - Pagina 7

Sfoglia online o scarica il pdf Manuale d'uso per Strumenti di misura AGS Mini Merlin CH4CO. AGS Mini Merlin CH4CO 16. Dual gas detector, methane & carbon monoxide gas
Anche per AGS Mini Merlin CH4CO: Manuale di installazione e funzionamento (16 pagine)

MINI MERLIN CH4CO
5.
Specification
Gas Sensor Type
Typical Sensor Measuring Range
Accuracy @ 25 ̊ C (77 ̊ F )
Initial Power Up Time
Low Level Alarm (pre-alarm)
High Level Alarm
Volt free BMS relays output
Operating Conditions
O/All Device Dimensions
Installation Standard
Rev: 08 05-19
Power Supply
110-120VAC, 50-60Hz (Max 3.1VA without load)
NG: semiconductor
CO: electrochemical
NG: 500 ~ 10,000ppm
CO: 0 ~ 1000ppm
± 1ppm ± 5% reading
One minute
NG 8% LEL by volume
CO 20ppm
NG 10% LEL by volume
CO
0.5A switching current (resistive load)
-32 - 122 ̊ F ; (0 - 50 ̊ C ) 0 - 95%RH, Non Condensing
Net Weight
8.54oz (242g) approx.
95(W)x140(H)x60(D)mm
3.7(W)x5.5(H)x2.4 (D)inch
Wall mountable
Model No:
Mini Merlin CH4CO
20 ppm for 2 hours
50 ppm for 1 hour
100 ppm for 10 minutes
300 ppm for 1 minute
USER GUIDE
7