Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione per Involucro AFL OptiNID 500. AFL OptiNID 500 8. Optical demarcation closure
COMPRESSION FITTING INSTALLATION
1. Ensure that the mounting hole is free from burrs and that the enclosure surface is smooth and free of debris.
2. Place the hex portion on the body (not the sealing nut) into the mounting hole.
3. Insert the cable through the fitting to the desired position
Note: For best practice, it is recommended that when working with the 9-port compression fitting that the
multi-port grommet be removed from the fitting body. Slit each end of the application appropriate ports and
align the grommet around the cables. Once all required cables are seated in the grommet, insert both the
cables and grommet back into the fitting body.
4. Tighten the sealing nut to hand-tight.
5. Using a wrench hold the body hex stationary while tightening the sealing nut with a second wrench.
Tighten until the cable is help securely in place.
6. Check to ensure that the fitting body is still screwed tightly into the panel.
DISASSEMBLE COMPRESSION FITTING –
CABLE REPLACEMENT
1. To disassemble for cable replacement, loosen the sealing nut.
2. Grip the disconnected cable and pull while turning the cable in the counter-clockwise direction.
SPLICING
Determine the location of the splice chip within
the splice tray.
1. Remove the paper backing from the splice chip to
expose the adhesive and place the chip at the desired
location within the splice tray.
2. Prior to splicing, ensure that adequate slack for both
the expressed fiber and the pigtail fiber is stored within
the splice tray. Mark fibers for splicing.
3. Clean the individual fiber per accepted local practice
using an approved fiber cleaner.
4. Follow accepted local practice for preparing and
splicing express fibers and pigtail fibers.
5. Once all splicing is complete, route the exposed fibers
inside the splice tray. (Figure 5)
Note: The tab on the splice chip may be used to
help organize loose tube bare fibers within
the splice tray.
6. Replace the splice tray cover.
INSTALLATION INSTRUCTIONS
OptiNID
(CONTINUED)
© 2017, AFL, all rights reserved. Revision A, 2.16.2017
Specifications are subject to change without notice.
6
500 Optical Demarcation Closure
®
Figure 5