Deaf Bonce AAP-350.1D Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Amplificatore Deaf Bonce AAP-350.1D. Deaf Bonce AAP-350.1D 20. Mono amplifiers
4. SELECTION OF THE DIAMETER OF POWER CABLES AND SPEAKER CABLES
S e l e c t i o n o f t h e d i a m e t e r o f t h e p o w e r c a b l e s
Use the table below to select the desired diameter based
on the length and the current consumption.
240-350
180-240
150-180
120-150
100-120
80-100
60-80
40-60
20-40
8-20
0-8
0-1 1-2 2-3 3-4 4-5 5-6 6-7 7-8
5 . W I R I N G D I A G R A M S
Connect the speaker cables from the positive and negative terminals of the speakers to the respective outputs of the amplifier
terminal marked with SPEAKER OUTPUT, as shown at the diagram. To connect the power wire supply it is necessary to use
special power cables. The fuse is placed in the holder and fixed in the cable cut. One end of the cable is connected to the positive
terminal of the battery, the second one – to the amplifier terminals marked with + 12V. Be sure to use a fuse with the parameters
sufficient for use in the system. The length and diameter of the grounding cable must conform to the length and diameter of the
cable + 12V. Connect one end to the negative terminal of the battery and the other end of the grounding cable to the terminals
marked with GND. Connect the head unit (HU) to low-level inputs of the amplifier using RCA cable.
Standard wiring diagram of mono amplifier to one subwoofer and to battery
Step 1. Connect the speaker cable from (+) terminal of the amplifier to (+) terminal of the subwoofer.
Step 2. Connect the speaker cable from (-) terminal of the amplifier to (-) terminal of the subwoofer.
Step 3. Connect one end of the power cable from (+) terminal of the battery and the second end to the amplifier terminal marked
with + 12V. Do not forget to protect positive power cable with appropriate fuse.
Step 4. Connect one end of the power cable from (-) terminal of the battery and the second end of the grounding cable to the
terminals marked with GND.
Step 5. Connect one end of the cable to the Remote output terminal at the HU and the second end to the amplifier terminal marked
with REM IN.
Caution!!! The minimum permissible connection load impedance is 1 ohm.
For models AAP-350.1D, AAP-550.1D, AAP-800.1D, AAP-1200.1D, AAP-1600.1D, AAP-2100.1D
Diameter
A.W.G mm²
1/0
2
4
8
10
12
14
16
18
Cable length (m)
.
the operating voltage is 9-15 V.
S e l e c t i o n o f t h e d i a m e t e r o f t h e s p e a k e r c a b l e s
Use the table below to select the desired diameter based
on the length and the power consumption.
25 000
20 000
15 000
53,5
10 000
33,6
8000
21,2
6000
8,4
4000
5,3
2000
3,3
1000
2,1
500
1,3
250
0,8
100
1-4 Om
4
0-1 1-2 2-3 3-4 4-5 5-6 6-7
Cable length (m)
5/FL
EN
Size
A.W.G mm²
5
16,8
8
8,37
10
5,26
14
2,08
7-8
EN