Gree TF04A Panel Manuale d'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale d'uso per Condizionatore d'aria Gree TF04A Panel. Gree TF04A Panel 9.

Gree TF04A Panel Manuale d'uso
TF04A Panel
(2)
Descending of return air grille:
After entering the cleaning status of return air grille and filter screen, press
the return air grille will descend.
(3)
Shut off in the descending process of return air grille:
During descending/ascending process of return air grille, press
return air grille will stop descending/ascending. Press
air grille will continue to descend/ascend. After ascending to designated location, the
return air grille will be stopped automatically. Maximum descending distance for the
return air grille is 3m.
(4)
Cleaning:
After the return air grille is descending to designated location, take down the air
filter screen on the return air grille, clean the filter screen with dust catcher or water;
in case the filter screen is too dirty (with greasy dirt), clean it with warm water (below
45°C) which is soluble in neutral detergent, then dry it.
NOTE:
Don't clean it with hot water over 45°C to avoid deformation or color fading; don't dry
it on fire, the filter screen might be burnt or deformed.
(5)
Reset of return air grille (ascending):
After installing the cleaned air filter screen, press the switch to reset the return
air frame and exit the clean mode or press
resetting is complete, if no operation in 3min, clean mode will be exited automatically
and the unit will be shut down.
to ascend the return air grille, after
4
or
or
again, the return
,
, the