Dean Forge Hembury 6 Manuale di istruzioni per l'uso - Pagina 6

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Stufa Dean Forge Hembury 6. Dean Forge Hembury 6 15.

In the event of a chimney fire
 Call the fire brigade
 Raise the alarm to let others in the house know
 Close down all the air controls of the stove, but be careful they could be very hot
 Move furniture, rugs and other objects away from the stove
 Check the chimney breast in other rooms for signs of excessive heat and move objects
away if necessary
Fitting Instructions for the Dean Stoves, Hembury 6 & 8
Before lighting the stove check that all installation instructions have been carried out.

Health And Safety Precautions

All work must be carried out to the requirements Health and Safety at Work Act 1974.
There must not be an extractor fan fitted in the room.
There must be an air vent for all stoves of 5 kilowatt and over or meet current building
regulations.
Stoves must be fitted to BS8303, BS6461 PT1-2 1984 building regulations.
All local regulations, including those referring to national and European standards need to be
complied with when installing the appliance.
N.B
A suitably qualified person must fit the stove. i.e. an experienced HETAS engineer or with the
supervision of building control,
As with all stoves, fireguards must be installed when young children are present.
Chimney
All Dean Stoves must have a minimum chimney height of 4m measuring from the stove outlet,
the chimney must not be less than 150mm (6") internal diameter.
These stoves are not suitable to be used in a flue-shared situation.
The chimney must be sound and of not too large in section. If not sound or too large, a liner
will have to be fitted; Stainless steel or ceramic liner suitable for solid fuel.
If the chimney draw is too high a flue stabilizer will have to be installed. When the chimney is
warm the draw should not be lower than 0.10 water gauge.
6