Gree NEO12HP115V1A Manuale d'uso - Pagina 9

Sfoglia online o scarica il pdf Manuale d'uso per Pompa di calore Gree NEO12HP115V1A. Gree NEO12HP115V1A 12. High-wall ductless air conditioning & heating system
Anche per Gree NEO12HP115V1A: Manuale di avvio rapido (2 pagine)

Gree NEO12HP115V1A Manuale d'uso
TWD-0813-033 Neo Manual REV:Layout 1 9/27/13 11:15 AM Page 17
OPERATION OF WIRELESS REMOTE CONTROLLER
CHANGING BATTERIES AND ADDITIONAL NOTES
To change batteries, slide cover off battery compartment on back of remote controller. Remove
and safely discard old batteries. Insert two new AAA 1.5V dry batteries, using correct polarity.
Reattach back cover.
NOTE:
• If the remote controller will not be used for a long time, remove batteries to prevent
leakage damage.
• Be sure to aim the remote controller at the receiver of the main unit when operating.
• When remote emits a signal, icon will flicker; a tone will be heard when unit receives
that signal.
CHANGING BATTERIES
Remove
old batteries
EMERGENCY OPERATION
Use the Manual Override button to manual operate the unit if the remote controller is lost or
damaged. Lift up the front panel section on the indoor unit and locate the Manual Override button
on the right hand side. Press the Manual Override button to turn ON the unit.The unit will operate
in AUTO mode and will automatically select heating or cooling to maintain room temperature
between 64°F and 77°F. The indoor fan will operate in auto fan mode. Press the Manual Override
button to cancel Manual Override Mode and transfer control back to the remote controller.
Install
new batteries
Manual
Switch

SYSTEM FUNCTIONS

TIME GUARD
The neo System is equipped with many system safeties to provide safe, reliable operation and
comfort.The Time Guard function prevents rapid cycling of the compressor.The system has a
protective 3-minute time delay to restart the compressor after it has turned off.
INTELLIGENT DEFROST
The neo Intelligent Defrost function increases room comfort and saves energy by eliminating
unnecessary defrost cycles. In heating mode, the unit will monitor the outdoor coil for frost build
up. Once frost buildup has been detected, the system will switch into a defrost mode to remove
the frost. In defrost mode the front panel LED display will show "H1" and the indoor fan and
outdoor fan will turn off while the the system removes frost from the outdoor coil. Once the frost
has been removed, the front panel LED display show room setpoint and system will revert back
to normal heating operation.
POWER FAILURE MODE
Power interruptions are no problem for the neo system. User selections and system parameters
are stored in non-volatile memory. These parameters are retained during a power failure.When
power is returned, the neo system will automatically return to the last operating mode.
COLD BLOW PROTECTION
The neo system guards against the annoying COLD BLOW in heating mode.The system
constantly monitors the discharge air temperature. It will delay the indoor fan until the indoor
coil has warmed up to prevent blowing uncomfortable cool air into the room.
POLYMERIC AIR FILTER
The polymeric mesh filters save energy by preventing the indoor coils from being plugged with
dirt and lint.This economical and sturdy filter may be washed, vacuumed and reused.
Optional Function:
PHOTOCATALYTIC FILTER
Photocatalytic Air Filter is a second stage filter that oxidizes and effectively eradicates organic
contaminants in the air.This high-tech filter uses natural ultraviolet light with a titanium dioxide
catalyst to effectively eliminate 99.9% of bacteria and viruses and absorb odors for cleaner,
healthier indoor air.
15