Maiwe MIEN2208 Series Manuale d'uso - Pagina 13

Sfoglia online o scarica il pdf Manuale d'uso per Interruttore Maiwe MIEN2208 Series. Maiwe MIEN2208 Series 19. Industrial ethernet switch
Anche per Maiwe MIEN2208 Series: Manuale d'uso (5 pagine)

Maiwe MIEN2208 Series Manuale d'uso
MIEN2208 Series Unmanaged Industrial Ethernet Switch
MIEN2208 series MIEN2208-S / 2S / 4S type switch side panel is
equipped with a 5-position lock 5.08mm pitch terminal
MIEN2208-S / 2S / 4S model power supply and relay terminal schematic
power input
The DC power supply models of MIEN2208 series switches support DC12
~ 48V power supply by default, users can choose DC48V, support dual power
input, and two power supplies are mutually backup.
The AC power models of MIEN2208 series switches support DC110 ~
370V and AC85 ~ 264V. When using AC models, V can only be input from V1 +
and V1-, V1 + is connected to the live wire L, and V1- is connected to the
neutral wire N. Connect V2 + and V2-, and pay attention to safety to prevent
electric shock.
Power-down alarm output
MIEN2208 series switches support alarm function. MIEN2208 and
MIEN2208GE models have normally closed nodes, and MIEN2208-S / 2S / 4S
models support normally closed nodes and normally open nodes. When the
switch works normally, the normally closed node is opened and the normally
open node is closed. When the system is powered off, the normally closed
node is closed and the normally open node is opened. The recommended
switch load capacity of the relay is 1A (24VDC). Users can use relay contact
- 9 -