Agua CW502 Manuale di installazione e istruzioni per l'uso - Pagina 8
Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Cappa di ventilazione Agua CW502. Agua CW502 15. High power range hood. cw500 series
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is fitted with an electrical junction box with 3 wires, one of which (green/yellow)
serves to ground the appliance. To protect you against electric shock the green-yellow wire must
be connected to the grounding wire in your home electrical system and it must not be cut or
removed under any circumstances. Failure to do so may result in death or injury to persons.
1. Facing the front of the range hood remove the left knockout and the junction box cover
and install the conduit connector in junction box.
2. Run 3 wires; black, white and green, according to the National Electrical Code and local
codes and ordinances in ½" conduit from the service panel to the junction box.
3. Connect black wire from the service panel to black or red wire in the junction box, white-
to-white and green to green-yellow.
4. Check all light bulbs to make sure they are secure in their sockets.
5. Turn power on in service panel.
6. Check lights and blower operation.
8