Clearing Jams

TO PREVENT SERIOUS INJURY FROM ACCIDENTAL OPERATION,
BEFORE ANY MAINTENANCE OR REPAIRS ARE DONE (including clearing jams):
• Wear ANSI-approved safety goggles with side shields.
Other people in the work area must also wear ANSI-approved impact safety goggles with side shields.
• Release the trigger.
• Detach the air supply.
• Attempt to fire the Tool into a piece of scrap wood to ensure that it
is disconnected and is incapable of firing any fasteners.
• Empty the magazine and leave it open during service.
The Magazine is spring-loaded and may cause parts or a fastener to fly out of the Tool.
1. If a fastener is jammed in the
discharge area, remove it with pliers.
2. If a fastener is jammed in the magazine, pull the
Pusher all the way back to the engaged position.
Use a screwdriver to release the jammed fastener
by probing the openings in the magazine.
Item 69927
69928
For technical questions, please call 1-800-444-3353.
3. Pull out the jammed fastener and the remainder of
the fastener strip from the magazine.
Dispose of the remaining fastener strip;
it is likely bent or damaged and may cause repeated
jamming or damage to the tool if reused.
4. If the jam cannot be cleared using the method above,
have the tool serviced by a qualified technician.