Size of the air pipe and liquid pipe for hot water converter used for connecting to water tank
isφ12.7/φ9.5; size of the air pipe and liquid pipe for water tank isφ9.5/φ6.4. When hot water
converter connects to water tank, it requires connecting tube with size ofφ9.5 toφ12.7, andφ6.4
toφ9.5 (hot water converter has been equipped with connecting tube, the connecting tube should
be installed in water tank side).
Sketch map for installation of connection of side discharge outdoor unit, hot water converter
and water tank:
Notes:
① The hot water converter is equipped with upper and lower temperature sensor; they are connected in the air,
the upper temperature sensor corresponds to red terminal, the lower temperature sensor corresponds to
white terminal.
② Lead the upper water temperature sensor from water tank sensor outlet 1 to the upper water temperature
sensor terminal for hot water converter.
③ Lead the lower water temperature sensor from water tank sensor outlet 2 to the lower water temperature
sensor terminal for hot water converter.
④ Distance between hot water converter and water tank should not be over 10 meters.
Notes:
Horizontal distance between hot water converter and thermal insulating water tank should not be over 10
meters, and vertical fall should not be over 3 meters. It is recommended to install the thermal insulating water tank
in lower position, and hot water converter in the upper position, or install them in the same level.
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
Hot water converter of GMV5 Home Installation and Operation Manual
Fig.5.1
5