CAUTION!
PE must be grounded to ensure the inverter works more reliably.
After fastening the three wires with the terminal, combine every component
together.
C
4. Finally, insert the AC connection socket into the AC socket on the inverter audibly
snaps into place.
DANGER!
Danger to life due to high voltages in the inverter.
• Do not switch on the circuit breaker until the PV generator has been connected and
the inverter is securely closed.
5.3 Connection of the PV Generator (DC)
CAUTION!
Load Disconnection Unit
On the DC side out of each inverter there is a circuit breaker, in order that the
inverter can be safely installed, the circuit breaker must be switched off.