Aguilar DB 751 Manuale - Pagina 5
Sfoglia online o scarica il pdf Manuale per Apparecchiature musicali Aguilar DB 751. Aguilar DB 751 6. Hybrid bass head
Rear Panel:
Speaker Outputs:
Two Neutrik Speakon connectors are provided. Use 12 gauge or larger speaker cable for
proper connections.
Tuner out:
This output sends the signal to your connected tuner. This output will still be active
when you mute the DB 751.
Aguilar DB751
Diagnostic and Protection
The DB751 is equipped with a self-diagnostic and status/protection circuit. Upon power-
up, the unit's blue status LED will blink for approximately 45 seconds. During this time
several circuit parameters are verified, or allowed to become self calibrated.
1. The high B+ voltage to the preamp tubes is slowly ramped up, allowing the tube
heaters to warm up before full current is drawn by the valves.
2. DC offset at the amp's output is monitored. Only if none is present (normal condition),
will the unit proceed with the self-check protocol.
3. Temperature on the MOSFET heat sink is checked, and again only if normal
temperature is detected, will the status check continue.
4. If all the voltages, offsets, and temperature are in accordance with factory
specifications, then the amp's input, and output relays will be energized. This will then
cause the operate LED to illuminate and the status LED to stop blinking. The amp is now
ready for normal operation.
5. The circuit continues monitoring the above parameters to protect both the DB 751 and
the speakers connected to the amp in the event of unit or user error. This will be indicated
by the status LED's blinking.
5