Adey MagnaClean Professional2XP Installazione e assistenza - Pagina 4
Sfoglia online o scarica il pdf Installazione e assistenza per Sistemi di filtrazione dell'acqua Adey MagnaClean Professional2XP. Adey MagnaClean Professional2XP 5.
Anche per Adey MagnaClean Professional2XP: Istruzioni per l'installazione e la manutenzione (2 pagine)
4 10
11
1
1
O ring
The lid seal should be cleaned
and checked for wear when
servicing MagnaClean. It is
Best Practice to replace the
Hand tighten.
lid seal at each service.
Only use Silicon grease or
water to lubricate O ring.
Do not use flux or EP grease.
4 13
2
1
3
1 - Turn valves on.
2 - Vent.
3 - Wipe filter dry.
4 12
Tighten by a ¼ turn max.
Important - Do NOT
overtighten.
Multiple installation options
MagnaClean Professional2XP has been designed as a Bi-directional flow filter. The inline design and
360° rotational valves provide multiple installation options for both vertical and horizontal pipework.
This ensures greater flexibility within the tightest working environments.
4 2
4 1
4
4
4 5
7
4
4 3
4 6