Step-by-step
Add a suitable cleaner, such as MC5
5
to the system via the RapidFlush filter
canisters.
6
Re-fill and pressurise the central
heating system ensuring the radiators
are half-full. Check for leaks.
7
Turn on central heating system. Make
sure all radiator valves are fully open.
The radiators should be hot at the
bottom, cold at the top. Allow system to
reach temperature (over 70°C).
Turn OFF hot water circuit, bypass
8
valves and all the radiators ensuring
they are fully closed. Leave the furthest
radiator open. With the system running,
using ADEY's VibraClean tool attached
to an SDS drill, set to hammer only
mode with no rotary action and agitate
radiator for 15-20 seconds.
®