Majestic fireplaces VF Collection UVS36 Manuale d'installazione e d'uso per il proprietario della casa - Pagina 13

Sfoglia online o scarica il pdf Manuale d'installazione e d'uso per il proprietario della casa per Riscaldatore a gas Majestic fireplaces VF Collection UVS36. Majestic fireplaces VF Collection UVS36 20. The vf collection vent-free gas fireplaces
Anche per Majestic fireplaces VF Collection UVS36: Specifiche tecniche (2 pagine)

Nova SIT 820
• Gas Supply On
Pilot Lights with
Piezo Ignitor
Pilot Stays Lit
Pilot Lights Main
Burner
System OK
20000135
Troubleshooting
START
NO
YES
NO
YES
NO
YES
NO
YES
FP396A
UVHB-standing pilot troubleshooting
7/2/98
Majestic Fireplaces
CHECK
• Supply line hooked up
• Shutoff valve open
• Lockout has engaged. Wait
60 seconds and try again
• For spark at electrode while
depressing Piezo
1/8" gap to pilot hood needed
• All wiring connections
• Replace Piezo ignitor
• For air in lines
• Thermopile needs a minimum
325mV. Adjust pilot flame height
• All wiring connections
• Replace Thermopile
• Thermocouple needs a minimum
of 14mV.
• Defective valve. turn to pilot,
meter should read greater than
100mV. If not, replace
• Valve is turned on
• Wall switch is not turned on.
Watch for grounded wires!
• Thermopile needs a minimum
325mV.
• Plugged burner orifice
UVC / UVS Vent-Free Heaters
®
FP396A
13