MAINTENANCE & ADJUSTMENT
If the clamp leaves impressions or damages the string, it may be excessively tight and should
be adjusted by turning the Adjustment Knob counter clockwise to open the gap between the
jaws. The clamp jaws should be cleaned periodically to be free from dirt, oil, and any string
coating residue to grip properly. Knife sharpening stones are excellent for removing build-up
on the diamond coated surfaces and are available.
Adjusting the String Clamp Jaw
Spacing
The string clamps will need minor adjustments
according to what string type, construction,
and gauge you are using.
To adjust the gap (clamping pressure)
between the clamp jaws, insert the string
through the racquet as if you were beginning
the main strings. Clamp the strings and pull
tension. If the string slips through the jaws of
the clamp, tighten the clamp by squeezing the
Adjustment
Knob
clamp jaws together by hand while turning the
Adjustment Knob, in the clockwise direction.
Adjusting the Clamp Base Locking
Nut
In the event the Locking Lever rotation is
insufficient to ensure smooth operation of the
clamp base, very minor adjustments to the
Clamp Base Locking Nut can be made with
the supplied 17mm socket wrench. Tighten
or loosen the locking nut in very small incre-
ments to provide more clamping pressure or
running clearance as needed.
Quick Action Clamp Base Removal
Quick Action clamp bases can be removed
from the turntable for maintenance or clean-
ing by removing clamp stop located at the
end of the slot in the turntable. To remove the
clamp stop, remove the two screws holding
the clamp stop in place from the underside of
the turntable. Lift the clamp stop out of the
slot, slide the clamp base to the end of the
slot and lift it out. Replace the clamp base
and clamp stop in reverse order.