Gamma Scale GMC-315 Manuale operativo - Pagina 2

Sfoglia online o scarica il pdf Manuale operativo per Bilance Gamma Scale GMC-315. Gamma Scale GMC-315 6. Digital counting scale

1. Parameters and Specification

2. Operation Keys and Functions

3. Operation Procedure
4. RS232C Output
5. Use Guide
6. Battery Maintenance(Option)
1.1 Accuracy class: OIML III
1.2 Internal resolution ration: 500000
1.3 External resolution ration: 30000
1.4 Relative humidity: <= 90% RH (no condensation)
1.5 Display: 6 digit 0.56-inches LED
1.6 Power supply: AC adaptor of 9V 800mA, C+;
1.7 RS232C Output Baud rate: 1200 (optional)
1.8 Platter size: 300 x 250(mm)
1.9 Operation temperature: -10°C ~ +40°C
1.10 Capacity: 6kg, 15kg, 30kg
1.11 Units: kg/lbs switchable
2.1 ON / OFF Key
a. Used when switching on or off the power of PCB, see Item 3.1 for details;
b. Used when simple rectifying.
CONTENTS
1. Parameters and Specification
DC Option: 6V 1.2Ah rechargeable battery
2. Operation Keys and Functions
- 1 -