Green Brook KingShield Orion Range Manuale di avvio rapido - Pagina 2

Sfoglia online o scarica il pdf Manuale di avvio rapido per Accessories Green Brook KingShield Orion Range. Green Brook KingShield Orion Range 2. Infra-red motion sensor - wall switch

3. To install in a circular back box, push
sensor in to box and tighten the two
splay screws, refer to Dia:3.
Dia:3
1. Slide function switch to the PIR position
(furthest right).
2. Turn 'Time' control fully anti-clockwise and
'Lux' control fully clock wise refer to Dia:5.
3. Re-connect mains supply, allow 30 seconds
for the sensor to warm-up, and then
perform a walk-by in front of the sensor;
lamp should turn on and stay on for
approximately 10 seconds, and will go off if
no further movement is detected.
1. Turning Lux control fully clock wise, the sensor will operate in both daylight and darkness.
2. Turning Lux control fully anti-clockwise, the sensor will operate in darkness only.
3. Set control to operate at your required daylight level.
1.
Turning the time control fully anti-clock wise will set the on duration to 10 seconds +/- 3
seconds.
2.
Turning the time control fully clock wise will set the on duration to 7 minutes +/- 2 minutes.
After testing and control adjustment, replace the faceplates by clicking into position.
1. 'ON' position, light will be permanently on, and will ignore PIR control.
2.
'OFF' position, light will be permanently off, and will ignore PIR control.
3.
'PIR'position, light will be controlled by the sensors PIR control.
Light not coming on in PIR mode
Fuse has blown, check fuse located under the front plate.
Check that lamp is good.
Check there is nothing obscuring the PIR sensor.
Check that function switch is set to 'PIR'.
Intermittent operation
Check there are no curtains that can move in the wind.
Check there are no heating vents nearby.
ADJUSTING THE 'LUX' CONTROL
ADJUSTING THE 'TIME ON' CONTROL
FUNCTION SWITCH
TROUBLE SHOOTING
TECHNICAL INFORMATION
Rated Voltage:
IP Rating:
Ambient Light:
Time Delay:
Rated Load:
Detection Range:
Detection Distance:
Working Temp:
Working Humidity:
Power Consumption:
Installation Height:
Detection Moving Speed: 0.6 - 1.5m/s
Fuse Type:
PLEASE KEEP THESE INSTRUCTIONS
SAFE FOR FUTURE REFERENCE
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
i n f o @ g r e e n b r o o k . c o . u k
w w w. g r e e n b r o o k . c o . u k
4. To install in a square back box, push sensor
into back box and using two 3.5mm screws
secure to back box through the appropriate
mounting holes, refer to Dia:4.
Dia:4
TESTING
Dia:5
230V~50Hz
IP20
<3-2,000 LUX (Adj)
Min 10 sec ± 3 sec
Max 7 min ± 2 min
0W - 500W
5W - 200W
160
9M max (<24°C)
-20° - + 40°C
<93%RH
0.5W approx
1 - 1.8M
3A, 20mm X 5mm
/LED