Green Brook M22SM Istruzioni per l'installazione - Pagina 2

Sfoglia online o scarica il pdf Istruzioni per l'installazione per Accessories Green Brook M22SM. Green Brook M22SM 2. Safetysure twin rcd socket

Green Brook M22SM Istruzioni per l'installazione
N.B. Green/yellow earth wire may be
connected to either earth terminal.
Wiring insulation tests should be
completed before setting the
SafetySure RCD Socket to avoid
misleading instrument readings and
possible internal damage to the unit.
PLEASE CARRY OUT THIS SIMPLE TEST
PROCEDURE PRIOR TO EACH USE.
1. Press green (R) ON button.
2. Indicator window will turn red*.
3. Press white Test button (T).
4. Red window indicator will
disappear*. This means the RCD has
tripped successfully.
5. To reset – press green (R) ON button
and use as a normal socket.
* If indicator fails to work, do not use
and return to place of purchase.
NOTE 1:
If the red window indicator
disappears once the socket has been
reset and appliance is firmly plugged
in the socket, this may mean that the
appliance or the cable lead is faulty,
and should be checked by a
qualified electrician.
NOTE 2:
Remove this RCD from circuit before
performing any high voltage
insulation tests.
Rated voltage:
IP Rating:
Maximum operating current: 13A
Rated trip current:
Trip speed Typical:
RCD contact break:
Test/Reset buttons:
Rated Short-circuit breaking
and making Capacity:
Rated conditional
short-circuit current:
Dimensions:
Conforms to BS7288:2016 & BS1363:2016
This socket has been designed for storage
and use between -5°C and +40°C and at
an altitude of no greater than 2000 metres
above sea level. Care must be taken not
to subject the unit to misuse, such as
abnormal pollution by smoke, chemical or
flammable fumes, salt laden spray,
prolonged periods of high humidity or
other abnormal conditions.
Your GreenBrook Twin RCD Socket
is guaranteed for 12 months from
This does not affect your statutory rights.
Please keep these instructions
- Please pass instruction manual onto
TECHNICAL INFORMATION
GUARANTEE
the date of purchase.
for future reference
INSTALLER
the owner of the unit
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
WWW.GREENBROOK.CO.UK
230V AC
IP20
(3A inductive)
30mA
30mS
Double pole
Responsive to
both positive and
negative cycles
250A
1500A Power
factor range
.93 to .98
145mm x 85mm
x 35mm
50Hz