NOTE 1: If the red window indicator disappears once the socket has been reset and appliance is firmly
plugged in the socket, this may mean that the appliance or the cable lead is faulty, and should be
checked by a qualified electrician.
NOTE 2: Remove this RCD from circuit before performing any high voltage insulation tests.
IMPORTANT – FOR YOUR PROTECTION.
Electricity can be dangerous and the use of an RCD should not be regarded as a substitute for basic electrical
safety precautions. Always switch off from supply when working on equipment. This device will protect against live
and neutral leakage faults to earth, it will not protect against electric shock due to contact with both conductors,
short circuits between live and neutral, or a fault in the wiring supplying this device. Should your PowerBreaker Safety
RCD Socket repeatedly trip with an appliance connected or fail to trip when tested, in accordance with the
instructions, return to place of purchase.
To open the lid use your thumbs to un-clip the end snap-shut clips. The lid should then pop open.
If the unit needs cleaning it should be disconnected from the mains supply. Wipe the surface with a dry
cloth. Do not use a damp or wet cloth or a solvent based cleaning agent, as this may damage or impair
the safety of the product.
This equipment is intended for domestic & light commercial use only. It must be installed in accordance with
these fitting instructions. It should be fixed in the approved & conventional way to a solid or suitably safe
surface.
The equipment should be connected to a mains supply of the appropriate voltage (indicated on the
product). If you are unsure, consult a qualified electrician before fitting. No liability can be accepted if this
product is installed or used in any other way.
PLEASE NOTE: Electricity is dangerous and can kill. If you are in any doubt of how to fit your product or there
appears to be damage to the wiring, please consult a qualified electri
INSTALLER - Please pass instruction manual onto the owner of the unit.
Opening the lid
Cleaning
Disclaimer
+
L LIVE = (Brown or Red)
-
N NEUTRAL = (Black or Blue)
E EARTH = (Green/Yellow)
TECHNICAL INFORMATION
Rated voltage:
Maximum operating current: 13A (13A inductive)
Rated trip current:
Trip speed:
RCD contact break:
Electrical latching:
Working Temp:
Socket Dimensions:
Enclosure Dimensions:
Independently tested to:
IP Box Conforms To:
GUARANTEE
Your PowerBreaker Protekt IP66 RCD Socket
is guaranteed for 5 years from
the date of purchase.
This is in addition to your statutory rights.
Please keep these instructions for future reference.
WEST ROAD . HARLOW
ESSEX . CM20 2BG . UK
www.greenbrook.co.uk
Snap-Shut Clips
(Lift to open)
cian.
230V AC ~ 50Hz
30mA
Less than 20mS (typical)
Double pole
Passive
-5ºC - 40ºC
W147.5 x H86.5 x D12mm
W195 x H149 x D80mm
BS 7288:1990
BS 1363-2:1995
BS EN 61543:1996
IEC 60670-1 & IEC60670-22