Deckma GAS 3000 Manuale d'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale d'uso per Sistema di sicurezza Deckma GAS 3000. Deckma GAS 3000 10. General alarm system
8.
TECHNICAL DATA
Power Supply:
Current Consumption:
Dimensions:
Console cut-out:
Ingress Protection:
Weight:
9.
TERMINAL ASSIGNMENT
Terminal JP1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
Terminal JP2
1
2
3
Tel.: +49 (0)4105 / 65 60 – 0
E-mail:
24V DC
ca. 100mA max.
144 x 72 x 125 mm (h x w x d)
138 x 66 mm (h x w)
IP 44 (at front when mounted in console)
0.4 kg (without power supply unit)
+ 24V
Supply +24V DC
- GND
Supply - GND
NO
Relay output only of manually given signals
COM
potential free, (max. 1A / 30V)
NC
NO
Relay output of a continuous signal, as long as
COM
an automatic signal is activated.
potential free, (max. 1A /30V)
NC
NO
Relay output of manually and automatically
COM
given signals, potential free, (max. 1A / 30V)
NC
+24V DC
Supply for signal inputs In1-In2-In 3
In 1
In 2
Inputs for external activation of „General Alarm"
In 3
x
Must not be connected
x
Must not be connected
x
Must not be connected
x
Must not be connected
x
Must not be connected
NO
Relay output for unit failure
COM
potential free, (max. 1A / 30V)
Open during failure or when supply is removed
NC
* DECKMA GmbH *
Fax: +49 (0)4105 / 65 60 – 25
*
Internet:
www.deckma-gmbh.de